Specifications
© 2015 Digital Monitoring Products
205 or higher, and XR150/XR350/XR550 Series): This number limits the monthly incoming and
outgoing SMS messages allowed to be sent or received by the panel. This option displays if any
programmed destination is a cell phone number using NET or CELL communication or an email address
using CELL communication. If all destinations are email addresses using NET communication, this
option does not display.
A panel event that causes messages to be sent to destination cell phone numbers or destination email
addresses is counted towards the panel's monthly limit. For example, if an alarm message is sent to a
cell phone number and an email address using CELL communication, a total of 2 messages are counted
towards the monthly limit for the panel. SMS messages sent from a cell phone to the panel, including
status requests and InTouch™ SMS Text messaging commands, also count toward the monthly limit.
The limit is reset at midnight on the 14th of every month. Range is from 0 to 999. When 0 is entered,
there is no limit on the number of messages able to be sent or received by the panel. Default is 0.
Note: The SecureCom Wireless text plan selected for the panel should match or exceed the
programmed Monthly Limit.
SMTP Configuration
The remaining options will only appear if email messaging has been selected to be sent via network.
The options allow the email server to be selected by the installing dealer. Typically this will be the
email service provided by the installing dealer. This allows opportunity for additional services to be
provided to the end user.
SMTP Server: Enter the SMTP (Simple Mail Transfer Protocol) Server name. The SMTP email server is
responsible for sending the email to its destination. An example SMTP email server name is:
mail.somedomain.com. The domain should be the email server that will provide email support for your
alarm customers.
SMTP Server Port: The SMTP server port number is the port that the panel uses to initiate a TCP
connection with the email server. The default port is 25.
SMTP Username: Most SMTP servers require a username to send email. This will be sent to the SMTP
server in conjunction with the SMTP Password to provide email authentication to the server.
SMTP Password: Most SMTP servers require a password to send email. This will be sent to the SMTP
server in conjunction with the SMTP Username to provide email authentication to the server.
From Email Address: Enter the email address on file with the email service. This will show up in the
email messages as the sender's address.
Program > Device Setup
The Device Setup window allows you to change the configuration of the keypad bus on the panel. You
may change the types of devices connected to the keypad bus, and the areas or partitions where those
devices are assigned. The Device Setup screen varies by panel model.
XR150/XR350/XR550 Series and XR100/XR500 Series Panels: