Specifications
© 2015 Digital Monitoring Products
TCP Enabled (XR150/XR350/XR550 Series with Network, XR100N Version 114-121/XR500N
Version 103-121): When this option is enabled, the panel communicates over the network using
standard TCP protocol. When this option is not enabled, the panel communicates using UDP protocol.
The TCP communications default value is Not Enabled.
Passphrase (XR550 with Encryption/XR500E): When this option is enabled, the panel
communicates to host automation using encrypted data. If you leave the Passphrase blank, the panel
can communicate with iCOM-E units, but the data is not encrypted. To enable encryption type an 8 to
16-character Passphrase using alphanumeric characters. This Passphrase must be the same for the
iCOM-E Encrypted Network Alarm Router installed in the receiver and the panel. The Passphrase is
blank by default.
Note: DO NOT LOSE THE PASSPHRASE. A lost or forgotten Passphrase requires that the panel
and every iCOM-E unit reporting in to the same receiver be individually reprogrammed with a
new Passphrase.
734N Listen Port (XR150/XR350/XR550 Series and XR100/XR500 Version 209 or above):
Enter the port number that the 734N uses to send communication to the panel. This