Specifications

© 2015 Digital Monitoring Products
Program>Communication P aths
Paths
Account Number: The Account Number is a 1 to 5 digit number used to identify which panel is
sending a message. Enter the account number sent to the SCS-1R Receiver. Messages may be sent to
a central station or via PC Log Reports to a PC. The default is 12345.
NET, CELL, 232 and DD - The range of valid account numbers for a panel is 1 to 65535. For
accounts of four digits or less, do not enter leading zeros.
CID - Choose an account number between 1 and 9999.
Transmit Delay: Enter the length of time that the panel should wait before sending burglary reports
to the central station. Select a time from 1 to 60 seconds. Alarm bells and relay outputs are not
delayed during this period. Enter 0 (zero) to disable transmission delay.
Path: Up to eight communication paths may be programmed. Each path is designated as a primary or
backup communication route. Path 1 is always Primary but other paths may be programmed as
additional primary or backup.
Each primary path establishes a new path group. A path group is made up of the primary path and its