Specifications
© 2015 Digital Monitoring Products
2nd IP Port: Enter the second IP port number to be used in conjunction with the Second IP Address.
The IP port identifies the port used to communicate messages to and from the panel. The default IP
Port setting is 2001.
Program > Comm unicatio ns > Receiver 2 Tab
Alarms: Sends Abort, Alarm, Alarm Restoral, Ambush, Exit Error, and System Recently Armed reports
to Receiver 2.
Supervisory Troubles: Sends Supervisory, Trouble, Trouble Restoral, Force Armed, Zone Fault
reports, and Serviceman Messages to Receiver 2.
Opening / Closing and User: Sends Opening, Closing, Door Access, Late to Close, Unauthorized
Entry, Schedule and Code changes, Zone Reset, and Zone Bypass reports by user to Receiver 2.
Note: Door Access is a separate option when programming the XR150/XR350/XR550 Series,
XR100/XR500 Series, or XR200-485.
Test Timer: Enables the panel to send the automatic recall test report to receiver 2. The panel sends
the automatic recall test reports as determined by the programming in the Test Timer tab.
Backup: Enables receiver 2 to serve as a backup for Receiver 1 if Receiver 1 does not respond to
communication attempts by the panel.
Door Access (XR150/XR350/XR550 Series/XR500 Series, XR100 Series, or XR200-485 only):
Sends door access granted reports to Receiver 2.
Note: The door access granted report is only sent if the device number has also been selected
in Access Keypad Enable in the System Reports window.
1st Phone No.: Enter the primary phone number for communications with Receiver 2.
Note: The 1st Phone No and 2nd Phone No fields only display if you are sending reports from
the panel to a receiver.
2nd Phone No.: Enter the secondary phone number for communications with Receiver 2.
Note: All phone numbers can be up to 32 characters. You may program a 3-second delay in the
dialing sequence by entering the letter P. You may also program a dial tone detect by entering
the letter D. These characters are counted as part of the 32 allowable characters.
The following character information applies to XR150/XR350/XR550 Series and XR500 Series
panels only.
XR150/XR350/XR550 Series and XR500 Series Characters: For the 1st and 2nd phone numbers,
entering the letter P programs a 2-second delay in the dialing sequence. XR150/XR350/XR550 Series
and XR500 Series panels do not require a dial tone detect D. Dial tone detect is an automatic XR150/
XR350/XR550 Series and XR500 Series panel function. Enter the letter C to program a cellular area
code detect. Enter the letter T as the string first character to enable the CID message communication
format option. These characters count as part of the 32 allowable characters.
Note: You can place the "* 7 0 P" (Star, Seven, Zero, Pause) in the telephone number first
position to cancel Call Waiting. For example, program NET with second line DD and phone