Note: The door access granted report is only sent if the device number has also been selected
in Access Keypad Enable in the System Reports window.
Panic Test (XR150/XR350/XR550 with Network Series, XR500N, XR500E or XR2500F Version
209 or earlier): Allows the panel to send panic zone test verification and failure results to the central
station. Leaving this box empty instructs the panel to not send panic zone test results. The system
test start, stop, panic zone verification, and panic zone failure messages sent to the central station
and the trips count operation is the same as used under Walk test.
Note: When a Panic Test is initiated from the keypad and the Model 1116 wireless relay output
connected to an LED annunciator or a Model 1118 wireless output is installed, the LED
annunciator flashes quickly for five minutes.
1st Phone No.: Enter the primary phone number for communications with Receiver 1.
2nd Phone No.: Enter the secondary phone number for communications with Receiver 2.
Note: You may program a 3-second pause in the dialing sequence by entering the letter P. You
may also program a dial-tone detect by entering the letter D.
The following features are available for XR150/XR350/XR550 Series and XR100/XR500 Series panels
only.
XR150/XR350/XR550 and XR100/XR500 Series Characters: For the 1st and 2nd phone numbers,
entering the letter P programs a 2-second delay in the dialing sequence. Panels do not require a dial
tone detect D. Dial tone detect is an automatic XR500 Series panel function.
Note: You can place the "* 7 0 P" (Star, Seven, Zero, Pause) in the telephone number first
position to cancel Call Waiting. For example, program NET with second line DD and phone
number *70P555-1212, and you have NET with Call Waiting cancelled on the second line.
Caution: A call waiting cancel programmed on a non-call waiting telephone line, would prevent
communication to the central station.
XR150/XR350/XR550 Series/XR500 Series/XR100 Series Area Code Selection for Cellular
Communication: You can also enter a letter C in the first or second telephone number. When
entered, the characters before the C are only used with a 2nd LINE Cellular call is being made. All
other calls made on the main phone line only use the characters entered after the letter C. The letter C
is never dialed and is recognized by the panel as a marker only. The C character counts as part of the
32 allowable characters.
XR150/XR350/XR550 Series/XR500 Series/XR100 Series Automatic CID Communication:
You can place a letter T in the telephone number first position to allow a message to be sent to the
receiver using CID communications. Once the CID message is sent, subsequent messages are sent
using the communications method selected under Communication Type until another telephone number
with a T in the first position is encountered. This option allows capture by AES radio or CID backup
communication to a CID receiver using a specific telephone number.
The automatic backup CID communication feature allows for the following communication options:
DD with CID second number
NET with DD second line
NET with CID second line
NET with DD/CID second line
For example, program NET with second line DD and phone number T555-1212, and you have NET with
CID second line.