Note: If a priority zone is in a bad state, you will not be able to arm the area until the priority
zone is restored to normal.
Panel > System Status > Area Status
When you arm or disarm an area using the Area Status window, you will see one of the following pop-
up messages indicating the action performed.
Armed successfully.
Armed successfully. Some zones have been bypassed.
Armed successfully. Some zones have been Force Armed.
Disarmed successfully.
Unable to disarm. Command disabled in panel. The remote disarm option has been disabled. To
enable remote disarming, check the Remote Disarm box in Program > Remote Options.
Unable to arm. # bad zones. The area(s) cannot arm because there are non-bypassable zones
faulted.
Panel > System Status > Zo ne Status
To bypass a zone, select the zone from the list in the Zone Status window and click the Bypass button.
The zone remains bypassed until reset from Remote Link, reset from the keypad User Menu, or when
the area is disarmed.
Note: Use caution when bypassing. Be certain of the zone type and the implications of
bypassing before attempting to bypass a zone.
To reset a zone, select the appropriate bypassed zone from the list in the Zone Status window and
click the Reset button. This removes the bypass from that zone.
Panel > System Status > Output Status > Output tab
The Outputs Status window allows you to remotely turn on or off any of the output relays on a panel.
You may specify Steady, Pulse, Momentary, or Off for any of the outputs.
To control the output relays, click on the Output tab near the bottom of the window. Then type the
number of the output in the Output field at the bottom left corner of the Output Status window. You
may also select an output from the list by clicking once on that line.
After selecting an output, chose which action you wish to apply to that output by clicking on one of the
four buttons at the bottom of the window.
Steady: To activate the output continuously.
Pulse: To activate the output to pulse at 1-second intervals.
Momentary: To activate the output one time for 1 second.
Off: To turn off the output.