Troubleshooting guide
23
Tamper Trouble
[ TAMPER –TRBL ] displays when the enclosure is opened or removed or the J4 header goes
open, resulting in a signal transmission to the central monitoring station.
• If this occurs when one or more areas are armed, a tamper ALARM message is
sent.
• If this occurs when all areas are disarmed, a tamper TROUBLE message is sent.
The J4 Tamper header is for use with an optional DMP Model 306 Tamper Harness. The
harness connects to one or more tamper switches mounted inside the panel enclosure to
detect unauthorized opening or removal of the enclosure.
XR500 J4 Tamper header and Model 306 Tamper Harness wiring diagram
To clear [ TAMPER -TRBL ] from the display:
• When the Model 306 Tamper Harness is not installed, a jumper should be placed on both
pins of the J4 Tamper header.
• When the Model 306 IS installed- place a jumper on J4. Does the display clear?
YES - Close the tamper switch(es) and check the Model 306 for continuity. If harness or
switches are bad, replace the Model 306.
NO - Enter Programming and Initialize EVENTS. Exit Programming. The trouble should now
be cleared from the display.
TECH NOTE: Initializing EVENTS erases ALL EVENTS in the Event Buffer.
-NOTES-
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________
_____________