Specifications

6 XR150/XR350/XR550 Intrusion/Access/Fire Detection Specification
4.9 Graphic User Interface (GUI)
Entré – Access and Security Management Software
System Features:
A. The software shall be available in three package sizes.
Entré Lite™: Shall have 16 doors included, and a maximum of four XR150/XR350/XR550 Series panels, personnel
management, full reports, and event management.
Entré Business™: Shall have the same features as Entré Lite with the option of expansion to 96 doors maximum and up to
24 XR150/XR350/XR550 Series panels.
Entré Enterprise™: Shall have the same features as Entré Business with 96 doors included with the ability to expand to an
unlimited number of doors, users and XR150/XR350/XR550 Series panels.
B. Shall have simple user management, with the ability to import users from existing databases.
C. Shall be able to assign user access by group, facility or other parameters.
D. Shall have drop down lists for devices, user data and other information to facilitate fast and accurate searches.
E. Shall be able to view system status in one of a variety of views for simplified alarm monitoring management.
F. Shall have the capability to customize reports for added flexibility.
User Management:
A. It shall have the ability to import into Entré from existing systems via standard comma-separated value (CSV) format
files. It shall easily add new users, capture and edit their photo for badging or visual verification from within the
application.
B. User fields shall be fully customizable. Assign specific rights or events by user or by group. The software shall be able
to create effective/expiration time for users, limiting access to only certain times of the day, and only certain days, or
for only a defined period of time.
AES Encryption:
A. Entré Enterprise shall support the XR550 Series with Encryption panel AES (Advanced Encryption Standard) strong data
security for sensitive personnel and facility data.
Highly Customizable:
A. The software shall be extensively customizable to create a system that matches the end user’s application’s needs.
B. Shall define what events are considered “alarms,” and what response is required from the system operator.
C. Shall be able to tailor user data with up to 20 available user-defined fields.
Hierarchical Views:
A. The software shall have the ability to select from four different system views, with the ability to have multiple views
open simultaneously. Select the graphical Map view, tabular Event view, or hierarchical Tree view.
B. The software shall be able to click on a device or alert to access additional information and process the event. In text-
based views, software shall have simple drill downs to allow fast navigation to the desired item.
Powerful Search:
The software shall employ industry standard SQL database for quick and easy search to identify any desired device or
user which is compatible with nearly any database.
Single-System Control:
The software shall employ a network solution to manage installations and users from any location. A single, unified
database means there’s one badge, one face or one fingerprint, worldwide.