Specifications
12 XR150/XR350/XR550 Intrusion/Access/Fire Detection Specification
E. The system shall be capable of supporting Network communication with digital dialer backup, existing Ethernet data
networks, satellite communication, fiber optic networks, local area networks, wide area networks, cellular
communication, and retail data networks.
5.7 Network Communication
A. The control panel shall be capable of asynchronous network communication with a retry time between 2 and 240
minutes and a fail time of 2 and 240 minutes. If communication is unsuccessful the control panel shall be capable of
attempting backup communication through any of the available communication methods to the same receiver or a
backup receiver.
B. The control panel shall employee adaptive communication technology. Adaptive Technology allows a Backup
communication path programmed to use Network or Cellular to automatically ADAPT to the faster check-in rate of the
Primary path should the Primary path become unavailable, creating a seamless transition for communication of
messages. Select Adapt when programming the Checkin option. This allows a system to be fully supervised even if a
path fails, while also keeping wireless charges low when the network is good.
C. Network communication between the control panel and the receiver shall be in a proprietary communication format.
D. The control panel shall be capable of supporting Dynamic Host Communication Protocol (DHCP) Internet Protocol (IP)
addressing.
E. Underwriters Laboratories (UL) shall list network communication by the control panel for Standard or Encrypted Line
Security.
F. The control panel shall be capable of two-way network communication using standard Ethernet 10/100 BaseT in a LAN,
WAN, or Internet configuration.
G. The control panel shall be capable of communication by means of a 128-bit or 256-bit AES (Advanced Encryption
Standard) Encryption process certified by NIST (National Institute of Standards and Technology) to an SCS-1R receiver
with an SCS-104 line card or SCS-VR (SCS-VR currently supports 128-bit encryption only).
H. The control panel shall be capable of meeting ICD 705 Chapter 7 Intrusion Detection Systems (IDS) and UL 2050
standards.
I. The control panel shall be capable of sending text messaging to up to three Cellular Phone Numbers using cellular
communications.
J. The control panel shall be capable of sending the following SMS messages:
Zone Alarms by Zone Name AC Power Trouble and Restoral
Zone Troubles by Zone Name System Low Battery
Zone Bypass by User Ambush
Arming (Closings) by User Abort, Cancel and Alarm Verified by User
Disarming (Openings) by User Check-in by user
Late to Close