Specifications

XR100/XR100N Intrusion/Access/Fire Detection Specification 19
10.0 BURGLARY CONTROL SPECIFICATIONS
10.1 Burglary Standards
The Burglary system shall be listed as a Power Limited Device and be listed under the standards in the table below.
Each system shall be supplied with complete details on all installation criteria necessary to meet all of the listings.
Burglary Listings U.S. Government Standards
UL 365 Police Connect Burglar Meets ICD 705 Chapter 7 Intrusion Detection Systems
(IDS)
UL 609 Local Burglar Meets DoD/NIST SCIF Standards
UL 1023 Household Burglar Alarm System Units Meets ANSI/SIA CP-01-2010 False Alarm Reduction
UL 1076 Proprietary Burglar Canadian Burglary Listings
UL 1610 Central Station Burglar Alarm Units ULC C1023 Household Burglar Alarm System Units
UL 1635 Digital Burglar Alarm Communicator System
Units
ULC/ORD-C1076 Proprietary Burglar
ULC S304 Central Station Burglar Alarm Units
10.2 Area System
A. The system user shall be capable of selectively arming and disarming any one or more of eight (8) areas within the
intrusion detection system based on the user PIN code and/or keypad used. Each of the 142 zones shall be able to be
assigned to any of the eight (8) available areas. The system shall be capable of having up to a sixteen (16) character
length name programmed for each area.
B. The system user shall be capable of assigning an opening and closing schedule to all areas or to each of the eight
(8) areas separately. Each area shall be able to arm or disarm automatically by a schedule. The system shall have the
capacity for common areas that automatically disarm when any other area disarms and that automatically arm when
all others areas arm.
10.3 Home/Sleep/Away
The system shall be capable of being configured in a Home/Sleep/Away configuration for Residential applications. The
system shall consist of a Main House system and up to two Guest House systems within one single control Panel with
each house being controlled with its own keypad as if it were separate alarm systems.
10.4 All/Perimeter
The system shall be capable of being configured into the All/Perimeter configuration to enable the selective arming of
both the interior and perimeter when armed “All” or arming just the perimeter devices if arming “Perimeter”.
10.5 Zones
The system shall have a minimum of eight (8) grounded burglary zones available from the control panel, and
two floating ground powered zones for two wire type compatible smoke detectors. The system shall have the ability
to expand using the panel’s keypad bus for up to sixty-four additional zones. The system shall also have a built-in
zone expansion bus (LX-Bus) for an additional 100 zones of expansion. The system shall be able to expand up to 400
additional hardwire zones using the 461 interface adaptor and additional 481 (LX-Bus) expansion modules or the
ability to integrate up to 500 wireless zones for a total of 574 zones overall.
Additional expansion shall be available using the 463C, 464-263C or 464-263H Cellular Communicator which provides
for a combination of up to 100 protection zones or 100 relay outputs.
10.6 Burglary Equipment
Burglary detection equipment shall communicate to the system by way of the control panel loop expansion bus or
900MHZ bi-directional spread spectrum receiver. The detection equipment shall have a three (3) year warranty and
meet or exceed features offered in the products listed in Section 12.0 of this document.