Specifications

XR100/XR100N Intrusion/Access/Fire Detection Specification 17
8.0 Must meet ANSI/SIA CP-01-2010 Standards for False Alarm Reduction
The system shall be capable of meeting ANSI/SIA CP-01-2010 Standards for False Alarm Reduction.
8.1 Shall Meet Exit Delay Standards
Default – 60 seconds (Minimum 45 seconds)
Progress Annunciation – different sound last ten seconds of delay
Automatic Restart of running exit delay, one time upon re-entry
Recent Closing – signal sent if alarm within 2 minutes of Exit time expiration (change from 5 min)
Exit Error – Immediate local alarm and entry delay starts
8.2 Shall Meet Entry Delay Standards
Default – 30 seconds (Minimum 30 seconds)
Pre-Warning Silenced – after first digit code entry
Cancel Message sent if disarmed after alarm sent
8.3 Shall Meet Fail-to-Exit Standards
When perimeter and exterior areas are defined and the user does not leave the building before the system arms, the
system only arms the perimeter and leaves the interior unarmed
8.4 Shall Meet Automatic Restart Standards
The system shall stop the Exit countdown once and restart it to allow the user to pick up a forgotten jacket or
briefcase and exit the building without sending an alarm to the central station.