Datasheet

SPECIFICATION VALUE
Console Size 5” x 2.44” x 1.25” (12.7 cm x 6.2 cm x 3.18 cm)
Probe Size
(standard PN#1040) 2” x 3” x .88” (5.1 cm x 7.6 cm x 2.2 cm)
Probe Size
(under carpet PN # 1041) 2” x 3” x .18” (5.1 cm x 7.6 cm x .5 cm)
Power Requirements
(resting state) WB-200: 12V or 24V AC or DC • WB-350: 9V battery @ 1.8 micro amps
Power Requirements
(alarm condition) WB-200: 5mA @ 12, 24 VDC, 13.5mA @ 12, 24 VAC • WB-350: 9V battery @ 380 micro amps
Sensitivity Will not alarm due to high humidity or condensation
Approximate Battery Life 1 year (WB-350 only)
Operating Temperature Control and Probe 32° to 140° F (0° to 60° C)
Outputs WB-200: Form C (SPDT) 1 Amp @ 24Vac, 1Amp @ 30 VDC • WB-350: Open collector max to tripline- 30
Recommended Dist. Between Probes & Console 1-2 probes: 200ft (61 m) max. • 3 or more probes: 100ft (30.5 m) per probe
Recommended Max. Probes Per Console 6
SPECIFICATIONS
WB-200 & WB-350 WATERBUG™
1950 Excel Drive
Mankato, MN 56001
1-800-635-4269
In MN: 507-625-7231
FAX: 507-387-2488
www.winlandsecurity.com
DESCRIPTION PART #
Surface Sensor W-S-U
Under Carpet Sensor W-UC-U
Optional 12 VDC Power Supply 12VDCT
ACCESSORIES
W-S-U
W-UC-U
©2006 Winland Electronics Inc.
D-011-0024 Rev. B