Installation guide
XR5 Installation Guide Digital Monitoring Products
3
INTRODUCTION
System Components
3.1 Description
A basic XR5 system is made up of the alarm panel with built-in communicator, an enclosure, a 16.5 VAC
wire-in transformer, and a 12 VDC 7.0 Ah battery. You can add up to two alphanumeric Security Command
keypads and one or more LED Security Command keypads to the panel and also connect control and
annunciating devices to the panel’s Form C and annunciator outputs. Refer to section 6.6 in this guide
when calculating power requirements.
3.2 XR5FC Wiring Diagram
The XR5FC system below shows some of the accessory devices you can connect for use in various
applications.
Figure 1: XR5FC Wiring Diagram
Panel Reset
RED
BLACK
GREEN
Keypad bus
22 gauge min.
BLACK
YELLOW
RED
Cold Water Pipe
Earth Ground
Output Header J11
Two Form C (SPDT) Outputs.
Zone 2
AC
1234
78
10 11 12 13 14 15
16
AC B+ B-
9
RED YEL GRN BLK Z1B- Z2 -Z2+
1
2
3
4
J12
Z1A- Z1B+Z1A+
MODEL XR5
MAIN BACKUP
J11
N/C COM N/O N/C COM N/O
Output Header J12
Four Open Collector Outputs.
50mA at 30 VDC resistive
U
ses Model 300 Harness
Relay Sockets for Optional
Form C Outputs on J11
Requires Model 305 Relays
Telephone Connections
Zone 1
J10 Trouble Annunciator Header
S
S
Keypad
Model 690
Direct connect to
unswitched 120 VAC 60 Hz
Secondary Power Supply
Model 367 or 369 Battery 12 VDC
1.2 Amps max. charging current.
Up to 500mA auxiliary
current at 12 VDC from
Terminal 7.
16-Character Keypads
32-Character Keypads
10 Zone LED Keypads
56
BELL SMK
Zone 4
Zone
5
Bell Circuit
1.5 Amps at 12 VDC
Aux. Power
Ground
Alarm Input
Bell Input
Bell Out +
Bell Out -
Bell Trouble
Bell Troubl
e
10k W
Resistor
Model 308
Power
Supervision
Relay
(if code requires)
Keypad
Model 692F
30mA at 8 to 16 VDC.
Keypad
Model 770
100mA at 8 to 16 VDC.
+
3.3k W Resistor
Model 30
9
+
Smoke
Detector
Red
Black
Model 866
Style W Notification
Circuit Module
45 mA at 12 VDC
Output 1 Output 2
OUTPUT 1
OUTPUT 2
SILENCE/RESET
PUSH FOR ONE SECOND
Silence/Reset
Button
Silence/Reset
Header
17 18
Z3 -Z3+
19 20
Z4 -Z4+
21 22
Z5 -Z5+
W
W
Up to 100mA of current is available for
4-wire smoke detectors from terminal 6.
Bell Monitor
Zone 3
S
S
-
-
J13
Smoke
Detector
3.3k W
Resistor
Model 309
J14
Model 377
Trouble
Annunciator
M
odule
Model 320
16.5 VAC 40VA
wire-in transformer
3.3k W
Resistor
Model 309