Installation guide
Digital Monitoring Products XR5 Installation Guide
12
INSTALLATION
Form C Relay Outputs
12.1 Description
The XR5FC and XR5SL panels can provide two auxiliary Form C (SPDT) relays when equipped with DMP
Model 305 Plug-in Relays in sockets OUTPUT 1 and OUTPUT 2. Each relay is rated for 1 Amp at 30 VDC.
Each output provides one Common, one Normally Open, and one Normally Closed terminal. Field wiring
for the Form C relays connects to the 6-position terminal strip on the lower right corner of the XR5FC and
XR5SL boards.
The Form C relays can be operated by any of the functions listed below:
1) Activation by a zone condition 3) Fire alarm or Fire trouble
2) Communication Failure
Annunciator Outputs
13.1 Description
The XR5FC and XR5SL panels provide four open collector annunciator outputs that can be programmed to
indicate the activity of the panel’s zones or conditions occurring on the system. Open collector outputs do
not provide a voltage but instead switch to ground voltage from another source. Each annunciator output
is rated for 50mA at 30 VDC resistive.
Form C and Annunciator outputs operate together: The Form C outputs 1 and 2 are internally connected
to the Annunciator outputs 1 and 2. Any options assigned to Output 1 or 2 in the panel’s Output Options
programming applies to both outputs. While the Form C outputs each require a Model 305 Plug-in Relay,
the annunciator outputs will work without the relays.
The Annunciator outputs can respond to any of the conditions listed below:
1) Activation by zone condition
2) Communication failure
3) Fire Alarm or Fire Trouble
13.2 Harness Wiring
The Annunciator outputs are accessible by installing the DMP 300 Harness on the 4-pin header labeled J12.
The output locations are shown below:
Output Color Wire
1 Red 1
2 Yellow 2
3 Green 3
4 Black 4
Devices connected to the outputs must be located within the same room as the XR5FC and XR5SL panels.
Telephone RJ Connector
14.1 Description
Connect the panel to the public telephone network by installing DMP 356 RJ Cables between the panel’s J4
(MAIN) and J5 (BACKUP) connectors, and the RJ31X or RJ38X phone jacks on the 356 cable.
14.2 FCC Registration
The XR5FC and XR5SL panels comply with FCC part 68 and are registered with the FCC.
Registration number: CCK USA - 18660 - AL - R
Ringer Equivalence: 1.1B