Installation guide

XR5 Installation Guide Digital Monitoring Products
9
INSTALLATION
6.6 XR5FC and XR5SL Power Requirements
During AC power failure, the XR5FC and XR5SL panels, and all auxiliary devices connected to the panels,
draw their power from the battery. All devices must be taken into consideration when calculating the
battery standby capacity. Below is a list of the power requirements of the XR5FC and XR5SL panels. Add
the additional current draw of Security Command keypads, smoke detectors, and any other auxiliary
devices used in the system for the total current required.
XR5FC and XR5SL Standby Battery Calculations
Standby Battery Power Calculations Standby Current Alarm Current
XR5FC/XR5SL Panel
Relay Outputs 1-2 (ON)
Active Zone 1
Active Zones 2-5
521B/BXT Smoke Detectors
SLR-835B Smoke Detectors
Other 2-Wire Smoke Detectors
Bell Output (1500mA Max.)
Qty ______x
Qty ______x
Qty ______x
Qty ______x
Qty ______x
50mA
30mA
3.3mA
4mA
0.070mA
0.070mA
.1mA
______mA
______
______
______
______
______
______
______
Qty ______x
Qty ______x
Qty ______x
Qty ______x
Qty ______x
50mA
30mA
3.3mA
4mA
0.070mA
0.070mA
.1mA
______mA
______
______
______
______
______
______
______
______mA
690/690F Security Command Keypad
Annunciator (ON)
Qty ______x 77mA ______
Qty ______x 84mA
20mA
______
______
692F Fire Security Command Keypad Qty ______x 30mA ______ Qty ______x 70mA ______
790/790F Security Command Keypad
Active Zones (EOL Installed)
Annunciator (ON)
Qty ______x 77mA
1.6mA
______
______
Qty ______x
Qty ______x
84mA
*2mA
20mA
______
______
______
791 Easy Entry Keypad
Active Zones (EOL Installed)
Annunciator (ON)
Qty ______x 100mA
1.6mA
______
______
Qty ______x
Qty ______x
100mA
*2mA
20mA
______
______
______
793 Easy Entry Keypad
Active Zones (EOL Installed)
Annunciator (ON)
Qty ______x 92mA
1.6mA
______
______
Qty ______x
Qty ______x
120mA
*2mA
20mA
______
______
______
770, 771 Security Command Keypads
Active Zones (EOL Installed)
Annunciator (ON)
Qty ______x 100mA
1.6mA
______
______
Qty ______x
Qty ______x
100mA
*2mA
20mA
______
______
______
377 Trouble Annunciator Module 17mA ______ 17mA ______
Aux. Powered Devices on Terminals 7 and 6
Other than Keypads
______mA ______mA
Total Standby
Total Standby______mA x number of Standby Hours needed
Total Alarm
*Based on 10% of active zones in alarm
______mA
______ =
______mA
+
Total
Total Alarm
________mA-hours
________mA-hours
________mA-hours
X .0001
= ________Amp-hrs
______mA
Required