Specifications

Digital Monitoring Products 690/690F/790/790F/791/793 Installation Sheet
6
690/690F/790/790F/791/793 Installation Sheet Digital Monitoring Products
7
Installer Options Menu
The Security Command and Easy Entry keypads also contain Keypad Option and Keypad Diagnostic programs that
allow installers and service technicians to congure and test keypad operation.
Access the User Menu
You can only access the Installer Options Menu through the User Options function. After holding down the Back
Arrow and COMMAND keys for a few seconds, when the SET BRIGHTNESS prompt displays, enter the code 3577 (INST)
and press COMMAND. The display changes to KPD OPT (keypad options) KPD DIAG (keypad diagnostics) and STOP.
The keypad options menu allows you to set the keypad address, select supervised or unsupervised mode, change the
default keypad message, individually arm the 2-button Panic keys, and select Soft-Shunt, Request-to-Exit, and
4-digit entry cards.
Programming Keypad Options
KPD KPD
OPT DIAG STOP
Keypad Options (KPD OPT)
To program keypad options, press the left Select key under KPD OPT. The display
changes to CURRENT KEYPAD ADDRESS: # #.
CURRENT KEYPAD
ADDRESS: 01
Keypad Address
Set the keypad address from 01 to 05 with the XRSuper6 and XR20, from 01 to 08
with the XR40, XR200, XR2400F, and 01 to 16 with the XR200-485 and XR500 Series.
The factory default address is set at 01. To change the current address, press any
Select key and then enter the new address using the appropriate number keys on the
keyboard. It is not necessary to enter a leading zero for addresses 01 to 09.
KEYPAD MODE:
*SUP UNSUP
Keypad Mode
Congure the keypad for either supervised or unsupervised operation. You have the
option to supervise keypads with zones connected to them. Supervised keypads cannot
share addresses with other keypads. To enhance the supervision feature, assign an
output to the Device Fail Output in panel programming and connect a device to the
corresponding output that trips when the keypad fails. This provides notication at the
central station and the site. The other keypads do not display the device fail.
Unsupervised keypads can operate with other unsupervised keypads sharing the same
address. Zones cannot be used on unsupervised keypads. To change the current
setting, press the Select key under SUP or UNSUP. An asterisk appears next to the
selected option.
Note: An unsupervised address cannot be programmed for Device Fail Output.
DEFAULT KEYPAD MSG:
Default Keypad Message
Enter a custom message of up to 16 characters to appear on the keypad display top line
whenever that line is not used for any other purpose. Press any Select key to clear the
current display and use the data entry keys to enter a new custom display.
ARM PANIC KEYS:
*PN *EM *F1
Arm Panic Keys
Use this option to congure the top row Select keys as 2-button Panic keys. To enable
or disable a Panic, press the Select key under the appropriate display: PN (Panic), EM
(Emergency), and FI (Fire). Once the panic is enabled, an asterisk displays next to the
description. Refer to the Panic Key Options section earlier in this document.
ACTIVATE ZONE 2
SHUNT: NO YES
Zone 2 Shunt (790/790F and 791/793 only)
Select YES to enable the Soft-Shunt™ feature on zone 2. This zone provides the Soft-
Shunt™ for door contacts. Zone 2 must be programmed into the panel.