Installation guide
Digital Monitoring Products 690/690F/790/790F/693/793 Installation Guide
8
690/690F/790/790F/693/793 Installation Guide Digital Monitoring Products
9
NO. OF USER CODE
DIGITS: 5
Number of User Code Digits (693 and 793 only)
The keypad recognizes user codes from four to six digits in length. Press any Select key
to enter the user code digit length being used by the panel. Default is 5.
When searching the bit string from the reader for the user code, the digits are
identied and read from left to right. When a four-digit user code is selected only the
rst four digits of the string are read.
The table below identies the panel types, the required operating modes for the
arming/disarming feature, and the appropriate code conguration (4, 5, or 6 digits) for
each panel.
Operation
XR500 Series/
XR2500F
XRSuper6 XR20/XR40 XR200 XR200-485
Arms H/A
Disarms H/A
—
—
4-digit
4-digit
4-digit
4-digit
4-digit
4-digit
—
—
Arms A/P
Disarms A/P
—
—
—
4-digit
—
4-digit
—
5-digit
—
—
Arms Area(s)
Disarms Area(s)
—
4, 5, or 6-digits
—
—
—
4-digit*
—
5-digit*
—
5-digit
* During entry delay only. — Not available on this panel type.
Note: XR200-485 and XR200 Command Processor™ Panels recognize a user code
with a maximum of ve digits.
As of March 2005, XR500 Series and XR2500F Command Processor™ Panels
recognize a user code with a maximum of six digits.
DEGRADED MODE
RELAY ALWAYS OFF
Degraded Mode (693 and 793 only)
This option denes the relay action when communication with the panel has not
occurred for ve seconds. Press any top row Select key to display CHOOSE ACTION.
The default is Relay Always Off.
CHOOSE ACTION
OFF SITE ANY ON
Choose the Degraded Mode Action required.
Press the rst Select key to choose OFF [Default] (Relay Always Off)
— The relay does not turn on when any Wiegand string is received.
Off does not affect any REX operation.
Press the second Select key to choose SITE (Accept Site Code)
— Door access is granted when the Wiegand site code string received matches any
site code programmed at SITE CODE ENTRY.
For details refer back to the REQUIRE SITE CODE option.
Press the third Select key to choose ANY (Any Wiegand Read)
— Door access is granted when any Wiegand string is received.
Press the fourth Select key to choose ON (Relay Always On)
— The relay is always on.
CHOOSE ACTION
LAST
Press the CMD key to display the next action.
Press the rst Select key to choose LAST (Keep Last State)
— The relay remains in the same state and does not change when communication
is lost.
After choosing the action, DEGRADED MODE and the newly dened action display.
Programming is now complete.