Installation Guide SCS-1R Security Control Receiver DMP Receiver Help Line Technical Service 1-888-436-7832 International 1-417-831-9362 After hours receiver emergencies 1-417-831-2866
Security Control Receiver Model SCS-1R Installation Guide INDUSTRY CANADA NOTICE This Class A digital apparatus complies with Canadian ICES-003. © 2009 Digital Monitoring Products, Inc. Information furnished by DMP is believed to be accurate and reliable. This information is subject to change without notice.
Table of Contents Operator’s Quick Reference Acknowledging an Alarm Signal............................................... 1 LED Indicators....................................................................... 1 System Overview Description............................................................................ 2 Function................................................................................ 2 32-Character LCD Membrane Keypad....................................... 2 Printer...................
Table of Contents Model SCS-100 Line Card Description............................................................................ 9 Transmit Level........................................................................ 9 Echo Cancel Off .................................................................... 9 Installing the SCS-100............................................................ 9 Connecting the Phone Line .................................................... 9 Phone Line Monitor...................
Table of Contents LCD Membrane Keypad Configuration Internal Speaker Operation....................................................17 LCD Backlighting...................................................................17 Display Options.....................................................................17 Keypad Options and Diagnostics.............................................17 Keypad Options..................................................................18 Accessing Keypad Diagnostics................
Introduction Operator’s Quick Reference This section explains basic operation for the operator. Acknowledging an Alarm Signal Press the key labeled ACK, or any top row Select key, to acknowledge an alarm. When the SCS-1R is in normal mode, the alarm message displays in the LCD display. If you are in programming when an alarm is received and requires acknowledgement, the ACK LED lights and the keypad begins to beep. If more than one message is received, the Message LED also lights.
Introduction System Overview Description The SCS-1R Security Control Receiver system from DMP is a full featured digital dialer and data network capable alarm receiver. The receiver provides a 32-character LCD display for viewing incoming messages and a built-in membrane keypad for acknowledging messages and configuring the SCS-1R system. Function The SCS-1R Receiver system provides central stations with computerized monitoring of DMP Command Processor™ panels.
Introduction System Block Diagram 120 VAC Input UPS Brownout Input J1 Cooling Fan Model SCS-130 Transformer Card Model SCS-110 Modem Rack Supply Card J2 Modem Rack Backplane J3 Model SCS-208 Power Cable RJ11X Cable or Ethernet Cable 10-Conductor Flat Cable Model SCS-120 Multibus Power Supply Card Multibus Backplane Line 1 4 Line 4 5 3 2 Line Card Connector J6 Port Line 2 Line 3 Line 5 Cable A1 Port Port A2 A1 Cable A2 Cable A3 J15 Keypad Port A3 1 Model SCS-150 Receiver Processor Bo
Introduction Installation Checklist Refer to the Hardware Description section of this guide for installation, setup, and operating information. SCS-1R Faceplate To lower the SCS-1R faceplate, turn the two screws located in the top corners of the SCS-1R. The front of the SCS-1R opens on a hinge to allow access to the inside of the SCS-1R. Close the SCS-1R system by raising the front of the SCS-1R and securing the two screws in the top corners.
Installation Model SCS-1R Security Control Receiver Description The DMP SCS-1R Receiver ships from the factory with all of the necessary system components to provide two Digital Dialer lines and one line of Data Network receiving capability. This package can be expanded to include a maximum of five incoming communication lines. The SCS-101 Network Line Card allows you to connect a digital data network to the SCS-1R Receiver.
Installation Model SCS-RACK System Enclosure Description The SCS-RACK houses the receiver processor, power supply, line cards, and associated cables. The enclosure measures 8.75” high, 19” wide, and 12” deep. Modem Rack The SCS-RACK top portion holds the modem rack, which connects the SCS-110 Modem Power Supply Card and up to five line cards. The SCS-130 Transformer Card for connecting the 120 VAC mounts on the rear of the modem rack.
Installation Description Model SCS-150 Receiver Processor Board The SCS-150 is the main system processor for the SCS-1R Security Control Receiver and controls the line cards, the LCD display, the printer (if used), and data output to a host automation system. The SCS-150 contains the software for system operation, the line configuration, and all time keeping functions. Programming can be done from the front panel of the SCS-1R Receiver or via Remote Link version 1.47 or higher.
Installation Before changing the the dip switch settings on the SCS-150 board, first power down the SCS-1R receiver and remove the processor board. After setting the dip switches, plug the SCS-150 board back into the receiver and power up. Reset Programming To Factory Defaults Return the receiver programming in EEPROM to factory defaults using the procedure below. • Power down the SCS-1R and remove the SCS-150 board. • Set the dip switches to 1010. • Replace the SCS-150 board and power up.
Installation Model SCS-100 Line Card Description The SCS-100 provides for one incoming line of digital dialer (DD) communication to DMP Command Processor™ panels. Each line card includes one RJ11X cable for phone line connection from a customer supplied RJ11X connection block. Transmit Level The Transmit Level is the level of signal strength at which the SCS-100 transmits through the phone line. To adjust the transmit level, place the 2-pin jumper on the desired level on the J11 Transmit Level header.
Installation Model SCS-101 Network Interface Card Description The SCS-101 Network Interface Card provides for a connection from a digital data network to a port on the SCS-1R Receiver. Each card includes one eight-pin modular connector for digital data network connection. This allows the SCS‑1R Receiver to accept alarm and system messages over a network from DMP Command Processor panels. Refer to the SCS-101 Installation Guide (LT-0320).
Installation Model SCS-110 Modem Power Supply Card Description The SCS-110 provides power to a maximum of five line cards. Power is supplied through the modem rack backplane connectors without additional cabling. The SCS-110 also provides LCD and keypad connection, UPS system status, and the 120 VAC input monitoring information to the SCS-1R Receiver. Installing the SCS-110 Always remove power to the SCS-1R Receiver when installing or removing the SCS-110.
Installation Model SCS-120 Multibus Power Supply Card Description The SCS-120 provides power to the SCS-150 through the multibus backplane. The SCS-120 also monitors the SCS-150 condition, the SCS-110 Modem Power Supply Card voltage output, and its own internal voltages. Installing the SCS-120 Always disconnect power to the SCS-1R Receiver when installing or removing the SCS-120.
Installation Model SCS-130 Transformer Card Description The SCS-130 provides power to the SCS-110 Modem Power Supply Card and the SCS-120 Multibus Power Supply Card. Two terminals are provided for connecting 120 VAC to the system. A power cord is provided for connecting the multibus rack cooling fan. 3 Amp 250V COM J2 HOT J3 To fan AC Power Cord Installation Always remove power to the SCS-1R Receiver when installing or removing the SCS-130. 1.
Installation Model SCS-208 Power Cable Description The SCS-208 is a 2-foot cable that connects the different system voltages between the SCS-130 Transformer Card J3 and SCS-120 Multibus Power Supply Card J3. Installation The SCS-208 cable can be used in either direction, but is polarized on each end for proper installation to the J3 connectors.
Installation ULC Installation Recommendations 1. In order to give the digital alarm communicator transmitter the ability to disconnect an incoming call to the protected premises, telephone service should be of the type that provides for timed release disconnect. 2. Network access and domain access policies shall be set to restrict unauthorized network access and “spoofing” or “denial of service” attacks. 3.
Operator’s Guide Using the LCD Membrane Keypad Special Keys COMMAND Key The COMMAND key allows you to go forward through the configuration menu and each configuration step (or prompt). As you go through programming, the keypad display shows any current programming already stored in the panel memory. If the information does not need to be changed, press the COMMAND key to advance to the next step. After changing programming, press the COMMAND key to advance to the next option.
Operator’s Guide LCD Membrane Keypad Configuration Internal Speaker Operation The LCD Membrane Keypad speaker emits standard tones for key presses and alerts. LCD Backlighting The LCD backlighting turns on every time a key is pressed or the speaker sounds. The backlighting dims to medium brightness whenever the speaker is on. Display Options The LCD Membrane Keypad provides three keypad adjustments you can make to suit your environment.
Operator’s Guide Keypad Options KPD OPT KPD DIAG STOP Keypad Options (KPD OPT) To program keypad options, press the left Select key under KPD OPT. The display changes to CURRENT KEYPAD ADDRESS: # #. CURRENT KEYPAD ADDRESS: 01 Current Keypad Address The Membrane Keypad must be set to keypad address 01. This is the default setting and should not be changed. KEYPAD MODE: *SUP UNSUP Keypad Mode The Membrane Keypad can be set for either Supervised or Unsupervised operation.
Operator’s Guide Status Displays and SCS-1R Programming Receiver Startup Display When the SCS-1R powers up, the display shows the software version and date of version release. Time Display During normal operation the display shows the current time. Press the Command button to enter the OFF-NORMAL menu. Off-Normal Status Displays previous Fire, Fire Verify, Burglary, and Supervisory zones that have not restored.
Operator’s Guide Programming Through Remote Link Programming of the SCS-150 can be performed using Remote Link version 1.47 or higher. Connect the computer with Remote Link installed to the 25-pin connector Auxiliary Port on the back of the SCS-1R Receiver using an SCS-204 cable. Note: Each SCS-150 programming section in Remote Link is independent and changes should be sent to the receiver after programming is completed for each window.
Operator’s Guide Change Rec Key Sure? YES NO Receiver key changed RECEIVER Hours from GMT: 6 GMT Change Receiver Key After entering the desired Receiver Key and pressing COMMAND, the SURE? YES NO prompt displays. Press the Select key under YES to keep the new key, or under NO to use the previously stored key. Receiver Key Changed After pressing the Select key under YES, the display indicates that the receiver key has been successfully changed.
Operator’s Guide Host Automation The SCS-1R Host Automation programming section allows adjustments to optimize the SCS-1R performance with the host automation computer. The display shows the current setting for each prompt. Press any top row Select key to clear the display and enter the new information. Host Automation SCS-1R Menu Press any top row Select key to program Host Automation settings. Press the COMMAND Host automation key to advance to the next programming section.
Operator’s Guide Set System Time/Date This selection allows you to set the correct time and date on the SCS-1R. All changes made in this selection print to the Activity Log printer. The time entered here is sent to panels if the Time Change programming option is set to YES. SCS-1R Menu Time/date Time/Date Press any top row Select key to display the time and date. Press the COMMAND key to advance to the next section of programming.
Printout Explanations Printout Explanations General Description Note: UL central station applications must use a serial printer listed for Fire Protective Signaling Systems. The SCS-1R prints out two general types of messages: changes in the system information and messages received from DMP Command Processor panels. The message line for system changes is bracketed by double asterisks with the time of occurrence printed at the far right.
Printout Explanations Door Access This message lists the user name accessing the door strike relay and the door number that is being accessed. The door number matches the keypad address operated by the user. This message prints on the Activity Log only. Acknowledgment of Fire Alarms and Troubles This message is listed each time the operator acknowledges a fire type zone alarm or trouble message. The message includes the account number, zone number, and the acknowledged condition.
Important Information Use the table below to record the reciever key for your SCS-1R Receiver. Keep this sheet and the rest of the manual in a safe location for future reference.