User`s guide
ePAD Programming Guide Digital Monitoring Products
11
Optional Programming with a DMP LCD Keypad
After properly installing the ePAD according to the directions in the ePAD 5.0 Mobile Keypad Installation Sheet (LT-
0545), you may program the ePAD using a DMP LCD keypad. Connect the keypad to the ePAD using the included
Model 330 Programming cable.
Note: The keypad used for programming must be set to Address 1 (one) and must be supervised.
Connect the Model 330 4-wire harness to the J2 Programmer 4-pin header on the ePAD. Connect the other end of the
4-wire harness to the keypad used for programming. After a few moments, ePAD PROGRAMMER displays indicating
the ePAD is ready to be programmed.
Press the COMMAND key to begin programming. Press any Select key to clear the display and enter new information.
After you enter the proper information for each programming prompt, press the COMMAND key to advance to the
next programming option. Use the Back Arrow key to return to the previous programming option and to backspace.
Note: The ePAD does not save programming changes until the Stop programmer option is performed.
Refer to the beginning of this guide for a description of the ePAD addresses, such as the IP and Gateway Addresses.
All addresses, such as the Local IP and Gateway, must follow the conventions for IP Addresses: 12 characters,
including leading zeros. The periods (.) automatically appear. For Example, 192.168.000.251 is the proper format for
an Address.
LOCAL IP ADDRESS
192.168.000.251
Local IP Address
Enter the ePAD IP address using digits 0 through 9. The default IP Address is
192.168.000.251. Be sure to enter leading zeroes in all IP Addresses.
If the ePAD is installed behind a router, enter a static IP Address for the ePAD within the
proper range of the available router IP Addresses.
GATEWAY ADDRESS
192.168.000.125
Gateway Address
Enter the local gateway IP address assigned to the ePAD. The default Gateway IP
Address is 192.168.000.125.
SUBNET MASK
255.255.255.000
Subnet Mask
Enter the ePAD Subnet Mask using digits 0 through 9. The default Subnet Mask is
255.255.255.000.
hTTP PORT
80
HTTP Port
Enter the HTTP Port assigned to the ePAD. The recommended range is 2000 through
65535. The default HTTP Port is 80.
Note: If an HTTP Port other than 80 is entered, the HTTP port number must follow the
IP Address when entering the IP Address in the address eld of the Internet Browser.
For example, if the HTTP Port is 2005 and the IP Address is 192.168.000.251, you enter
http://192.168.000.251:2005.
UPGRADE PORT
9999
Upgrade Port
Enter the port number used when upgrading the ePAD using Remote Link™. This must
match the settings used in the Remote Link Program Panel Information screen for
rmware update. The recommended range is 2000 - 65535. The default value is 9999.
SESSION TIMEOUT
10
Session Timeout
Enter the length of time, from 0 to 99 minutes, that the ePAD waits before
disconnecting when no activity is detected. When 0 (zero) is entered, a Session
Timeout never occurs. The default Session Timeout time is 10 minutes.
KEYPAD ADDRESS
4
Keypad Address
Enter the keypad address, 1 through 16, that the ePAD occupies on the panel keypad
bus. The default address is 4.
Note: If the panel requires Device Setup programming, activate the corresponding
device number in Device Setup. For example, if 5 is entered here for the Keypad
Address, enter 5 in Device Setup during panel programming.