Installation guide

12 LCD Keypad Installation Guide
SITE CODES 5-8
> > > >
Site Codes 5-8
(7063/7063A, 7073/7073A, 7163/7173 only)
Enter site codes 5-8 (left to right separated by > sign). Press
the Select key below the > sign to add, delete, or change the
site code and press COMMAND. Site code range is 0-999.
NO OF USER CODE
DIGITS: 5
Number of User Code Digits
(7063/7063A, 7073/7073A, 7163/7173 only)
The keypad recognizes user codes from four to twelve digits
in length. Press any Select key to enter the user code digit
length being used by the panel. Default is 5. For an XR100/
XR500 Area System or XR150/XR350/XR550 Area System use
4 to 10 digits (typically 5). For all other systems and panels,
use 4 digits.
Any selection above 5 digits require entry of the custom card
denitions with custom site and user code positions for the
Wiegand string.
When searching the bit string for the user code, the digits
are identied and read from left to right.
NO COMM WITH PANEL
RELAY ALWAYS OFF
No Communication with Panel
(7063/7063A, 7073/7073A, 7163/7173 only)
This option denes the relay action when communication
with the panel has not occurred for ve seconds. Press any
top row Select key to display CHOOSE ACTION. The default is
Relay Always Off.
Choose the No Communication with Panel Action
required.
Press the rst Select key to choose OFF
(Relay Always Off) —The relay does not turn on when
any Wiegand string is received. Off does not affect any
REX operation.
Press the second Select key to choose SITE
(Accept Site Code) — Door access is granted when the
Wiegand site code string received matches any site
code programmed at SITE CODE ENTRY. For details refer
back to the REQUIRE SITE CODE option.
Press the third Select key to choose ANY
(Any Wiegand Read) — Door access is granted when any
Wiegand string is received.
Press the fourth Select key to choose ON
(Relay Always On) — The relay is always on.
CHOOSE ACTION
OFF SITE ANY ON