Specifications

G0
65VN01 V2 Ver. 1.2
21/24
G
065VN01 V2
8. Reliability Test Criteria
Items Required Condition Remark
Temperature Humidity Bias
300Hr Note 2
High Temperature Operation
80 *, 300Hr Note 2
Low Temperature Operation
-3 300Hr Note 2
High Temperature Storage
80 *, 300 hours Note 2
Low Temperature Storage
-30, 300 hours
Note 2
Thermal Shock Test
-30/30 min, 80*/30 min, 100cycles
Note 2
Hot Start Test
80*/1 Hr (min.), power on/off per 5 minutes, repeat 5 times
Note 2
Cold Start Test
-30/1 Hr (min.), power on/off per 5 minutes, repeat 5 times
Note 2
Shock Test
(Non-Operating)
50G,20ms,Half-sine wave, (±X, ±Y, ±Z) Note 2
Vibration Test
(Non-Operating)
1.5G, 10~200~10Hz, Sine wave, 30mins/axis, 3 direction (X, Y, Z) Note 2
ESD
Contact Discharge: ±8KV, 150pF(330Ω) 1sec, 8 points, 25 times/point
Air Discharge: ±15KV, 150pF(330Ω) 1sec, 8 points, 25 times/point
Note 1,2
Attitude Test
Operating: 14,000 ft, Ramp: 2000 ft/min, 8hrs
Non-operating: 40,000 ft, Ramp: 2000 ft/min, 24hrs
Note 2
Note1: According to EN61000-4-2 ESD class B criteria, some performance degradation is allowed. TFT-LCD module
is self-recoverable, no data lost and no hardware failures after test.
Note2:
Water condensation is not allowed for each test items.
Each test is done by new TFT-LCD module. Don’t use the same TFT-LCD module repeatedly for reliability test.
The reliability test is performed only to examine the TFT-LCD module capability.
To inspect TFT-LCD module after reliability test, please store it at room temperature and room humidity for 24
hours at least in advance.
*: Panel surface temperature
AUO Confidential For DATAMODUL Internal Use Only / 2012/10/11
Data Modul AG - www.data-modul.com