Specifications

G121SN01 V4 rev. 1.4
P
age 7/24
G
121SN01 V4
Note 2: Definition of 5 points position (Display active area: 246mm (H) x 184.5mm (V))
1 2
3
4 5
H / 4
H / 4
H /4
H /4
H
W
W / 4 W / 4 W / 4 W /4
Note 3: The luminance uniformity of 5 points is defined by dividing the minimum luminance values by the
maximum test point luminance
Note 4: Definition of contrast ratio (CR):
Note 5: Definition of response time:
T
he output signals of photo detector are measured when the input signals are changed fromWhite” to
“Black(falling time) and from “BlacktoWhite” (rising time), respectively. The response time interval is
between 10% and 90% of amplitudes. Please refer to the figure as below.
Note 6: Definition of viewing angle
al and
18 vertical range (off-normal viewing angles). The 180° viewing angle range is broken down as below:
90° ) horizontal left and right, and 9 (Φ) vertical high (up) and low (down). The measurement direction is
typically perpendicular to the display surface with the screen rotated to its center to develop the desired
Minimum
Brightnes
s of
five
poin
t
s
δ
W9
=
M
aximum
Brightness of
five
points
Contrast ratio (CR)=
Brightness on the “White” state
Brightness on the “Black” state
100
90
10
0
%
Optical
response
White
Black
White
Tf
Tr
90
10
0
Optical
response
White
Black
White
Tr