6.6 Power ON/OFF Sequence
VDD power and lamp on/off sequence is as below. Inte
rface signals are also shown in the chart. Signals from
any system shall be Hi-Z state or low level when VDD is off.
Power ON/OFF sequence timing
Value
Parameter
Min. Typ. Max.
Units
T1 0.5 - 10 [ms]
T2 30 40 50 [ms]
T3 175 - - [ms]
T4 10 - - [ms]
T5 10 - - [ms]
T6 0 - - [ms]
T7 10 - - [ms]
T8 100 - - [ms]
T9 0 16 50 [ms]
T10 - - 10 [ms]
T11 1000 - - [ms]
The above on/off sequence should be applied to avoid abnormal function in the display. Please make sure to turn
off the power when you plug the cable into the input connector or pull the cable out of the connector.