Specifications
G150XG01
V3 rev 1.0
6/28
2.2 Optical Characteristics
The optical characteristics are measured under stable co
nditions at 25 (Room Temperature):
Item Unit Conditions Min. Typ. Max. Note
White Luminance
[cd/m2]
100% Dimming
(center point)
320 400 - 1
Uniformity
%
9 Points
75
80 - 1, 2, 3
Contrast Ratio
400
700 - 4
Cross talk
%
-
1.2 1.5 5
[msec]
Rising
-
5.7
[msec]
Falling
-
2.3
Response Time
[msec]
Raising + Falling
-
8
6
[degree]
[degree]
Horizontal
(Right)
CR = 10 (Left)
70
70
80
80
-
-
Viewing Angle
[degree]
[degree]
Vertical
(Upper)
CR = 10 (Lower)
50
70
60
80
-
-
7
Red x
0.577
0.627
0.677
Red y
0.298
0.348
0.398
Green x
0.288
0.338
0.388
Green y
0.539
0.589
0.639
Blue x
0.100
0.150
0.200
Blue y
0.029
0.079
0.129
White x
0.263
0.313
0.363
Color / Chromaticity
Coordinates
(CIE 1931)
White y
0
.279 0.329
0.379
Color Gamut %
-
60 -
Gamma Value
-
2.2 - 8
Note 1: Measurement method
Equipment Pattern Generator, Power Supply, Digital
Voltmeter, Luminance meter (SR_3 or equivalent)
Aperture
Test Point Center
Environment < 1 lux
LCD Module
SR_3 or
equivalent
Measuring distance
Module Driving Equipment
Data Modul AG - www.data-modul.com
7