Technical data

TECHNICAL REFERENCE MANUAL
8.5 Error codes
No. Format Meaning
203
@E203
wrong syntax in command, or prohibited command, or prohibited parameter in
command entry, or non-valid result
204
@E204
Dimension error
210
@E210
Not in tracking mode, use command sNf to start tracking mode first.
211
@E211
Sampling too fast, set the sampling time to a larger value using sNf
(also for command sNA)
212
@E212
Command cannot be executed, because in tracking mode, first use command sNc
to stop tracking mode.
213
@E213
Baud rate could not be set. (Contact Dimetix)
217
@E217
Parameter set-up incorrect (Contact Dimetix)
221
@E221
Parity error (Prior to contacting Dimetix please check the Terminal settings)
222
@E222
Interface buffer overflow
(Contact Dimetix if error occurs when sending less than 24 characters)
223
@E223
Interface framing error
(Contact Dimetix)
224
@E224
Command buffer overflow
(Contact Dimetix if error occurs when sending less than 24 characters)
252
@E252
Temperature too high
(contact Dimetix if error occurs at room temperature)
253
@E253
Temperature too low
(contact Dimetix if error occurs at room temperature)
255
@E255
Received signal too weak, distance < 200mm
(Use different target and distances, if the problem persists, please contact Dimetix)
256
@E256
Received signal too strong
(Use different target and distances, if the problem persists, please contact Dimetix)
257
@E257
Too much background light
(Use different target and distances, if the problem persists, please contact Dimetix)
260
to
299
@E260
to
@E299
Hardware failure (Contact Dimetix)
not
listed
Hardware failure (Contact Dimetix)
Before contacting Dimetix, please collect as much information as possible.
Distance Laser Sensor Page 31/40