Technical data
TECHNICAL REFERENCE MANUAL
8.4.5 Tracking (h)
Triggers continuous measurement of the distance. The measurements are continued until the next command is
issued or until a fault arises. The status LEDs and the digital outputs are updated corresponding to the new
measured distance.
Command input:
h<trm>
Return data
Successful:
31..06+xxxxxxxx 51....+00000000<trm>
xxxxxxxx:
Distance in 1/10 mm
Error:
@Ezzz<trm>
zzz:
Error code
8.4.6 Signal measurement (k)
Triggers continuous measurement of the signal strength. The measurements are continued until the next
command is received or until a fault arises.
Command input:
k<trm>
Return data
Successful:
53....+xxxxxxxx<trm>
xxxxxxxx:
Signal strength of the returned light in mV
Error:
@Ezzz<trm>
zzz:
Error code
8.4.7 Temperature measurement (t)
Triggers measurement of temperature.
Command input:
t<trm>
Return data
Successful:
40....+xxxxxxxx<trm>
xxxxxxxx:
temperature in 1/10°C
Error:
@Ezzz<trm>
zzz:
Error code
8.4.8 Laser ON (o)
Switches laser ON.
Command input:
o<trm>
Return data
Successful:
?<trm>
Error: @Ezzz<trm>
zzz:
Error code
Distance Laser Sensor Page 28/40