Technical data

TECHNICAL REFERENCE MANUAL
8.3.3 Set analog output min level (sNvm)
This command sets the minimum analog output current level (0 or 4 mA).
Command input:
sNvm+x<trm>
N:
Module number (0..9)
x: Minimum output for analog out
0: Minimum signal is 0 mA
1: Minimum signal is 4 mA
Return data:
Successful:
gNvm?<trm>
Error: gN@Ezzz
zzz:
Error code
8.3.4 Set analog output value in error case (sNve)
This command sets the analog output current level in mA in case of an error. This level can be lower as the min
level set in 8.3.3 Set analog output min level (sNvm).
Command input:
sNve+xxx<trm>
N:
Module number (0..9)
xxx: Value in case of an error in 0.1mA
Return data:
Successful:
gNve?<trm>
Error: gN@Ezzz
zzz:
Error code
8.3.5 Set distance range (sNv)
Sets the minimum and maximum distances corresponding to the minimum and maximum analog output current
levels.
0...20mA 4...20mA
Aout
=
DIST
D
min
D
max
D
min
20 mA Aout
=
DIST
D
min
D
max
D
min
16 mA
4 mA
Aout Analog current output
DIST Actual measured distance
D
min
Distance programmed for the minimum output current
D
max
Distance programmed for the maximum output current
Command input:
sNv+xxxxxxxx+yyyyyyyy<trm>
N:
Module number (0..9)
xxxxxxxx: Minimum distance in 1/10 mm corresponding to 0mA / 4mA
yyyyyyyy: Maximum distance in 1/10 mm corresponding to 20mA
Return data:
Successful:
gNv?<trm>
Error: gN@Ezzz
zzz:
Error code
Distance Laser Sensor Page 23/40