Technical data

TECHNICAL REFERENCE MANUAL
7 Factory settings
7.1 Operation
Mode: Controlled
7.2 Communication parameters
Baud: 19200
Data bit: 7
Parity: Even
Stop bit: 1
7.3 Analog outputs
Min output: 4mA
Range min: 0m
Range max: 10m
Error output: 0mA
7.4 Module ID
ID Number: 0
7.5 Digital output 1 (DOUT1)
ON: 2m + 5mm = 2005mm
OFF: 2m - 5mm = 1995mm
7.6 Digital output 2 (DOUT2)
ON: 1m – 5mm = 995mm
OFF: 1m + 5mm = 1005mm
Distance Laser Sensor Page 18/40