3.2.3 Controlled mode
RS232
When using the RS232 interface only point-to-point communication is possible.
❢ Never connect multiple DLS-A(H)s on a RS232 serial line
RS422
It is possible to connect multiple devices on a single RS422 line. To ensure proper operation, strict Master-Slave
communication must be used. It is important, that the Master has full control of the communication and never
initiates a new communication before termination of the previous communication (answer from the DLS-A(H) or
timeout).
❢ Ensure, that all DLS-A(H)s are set to different ID numbers