Specifications
GENESIS B-40 SM-60 SM-100 DM-200 Q-200X
Continuous power output watts RMS, 20 Hz - 20 kHz, 0,1% distortion
Nom. power in 4Ω 2 x 20 W 2 x 30 W 2 x 50 W 2 x 100 W 4 x 50 W
Typical power in 4 Ω 2 x 30 W 2 x 45 W 2 x 75 W 2 x 130 W 4 x 70 W
Nom. power in 2 Ω 2 x 40 W 2 x 60 W 2 x 80 W 2 x 150 W 4 x 90 W
Typical power in 2 Ω 2 x 50 W 2 x 80 W 2 x 110 W 2 x 200 W 4 x 120 W
Bridge mode 4Ω nom. 60 Watt 120 Watt 160 Watt 300 Watt 2 x 180 W
Bridge mode 4Ω typical 90 Watt 150 Watt 240 Watt 425 Watt 2 x 240 W
S / N ratio, better than 100 dB 100 dB 100 db 100 dB 100 dB (A-weigthed)
Channel separation 60 dB 70 dB 70 dB 70 dB 60 dB
Input variable 0,2 - 3V 0,2 - 3V 0,2 - 3V 0,2 - 3V 0,2 - 3V
Power consumption:
idle 0,4 A 0,5A 0,8A 1,2A 1,3A
4Ω nom. power 8A 13A 19A 45A 45A
2Ω nom. power 16A 24A 35A 65A 65A
Dimensions (mm) 100x190x62 125x177x62 165x192x62 260x192x62 320x192x62
AMPLIFIERS IN CLASS AB:
TECHNICAL SPECIFICATIONS GENESIS AMPLIFIERS, series 2
AMPLIFIERS IN CLASS "A":
GENESIS SA-30 SA-50 DA-100 Q-100X P-300X*
Continuous power output watts RMS, 20 Hz - 20 kH, 0,1% distortion
Nom. power in 4Ω 2 x 15 W 2 x 25 W 2 x 50 W 4 x 25 W 4x40 W + 1 x 100 W
Typical power in 4 Ω 2 x 25 W 2 x 45 W 2 x 85 W 4 x 45 W 4 x 53 W + 1 x 130 W
Nom. power in 2 Ω 2 x 30 W 2 x 50 W 2 x 100 W 4 x 50 W 4 x 60 W + 1 x 200 W
Typical power in 2 Ω 2 x 45 W 2 x 75 W 2 x 140 W 4 x 75 W 4 x 78 W + 1 x 220 W
Typical power in 1 W 1 x 300 W
Bridge mode 4Ω nom. 60 Watt 100 Watt 200 Watt 2 x 100 Watt 2 x 100 W
Bridge mode 4Ω typical 100 Watt 160 Watt 300 Watt 2 x 160 Watt 2 x 130 W
S / N ratio, better than 100 dB 100 dB 100 db 100 dB 105 dB
Channel separation 70 dB 70 dB 70 dB 70 dB 70 dB
Input variable 0,2 - 3V 0,2 - 3V 0,2 - 3V 0,2 - 3V 0,2 - 2V
* P300X subchannel works in class AB
Power consumption:
idle 1,3 A 1,7A 3,3A 3,4A 3,8A
4Ω nom. power 8A 12A 22A 24A
2Ω nom. power 16A 23A 33A 46A 87A
Dimensions (mm) 125x177x62 165x192x62 260x192x62 320x192x62 450x192x62
6
BUILT-IN FILTERS
REC. CABLE SIZES FOR THE DC-FEED
Cable length: <1,5 m 1,5 - 5 m > 5 m
B-40/SA-30/50 6 mm
2
10 mm
2
16 mm
2
SM-60/SM-100 6 mm
2
10 mm
2
16 mm
2
DA-100/DM-200 10 mm
2
16 mm
2
21 mm
2
Q-100X 10 mm
2
16 mm
2
21 mm
2
Q-200X 16 mm
2
21 mm
2
33 mm
2
Mono-250/P-300X 16 mm
2
21 mm
2
33 mm
2
Q-100x, Q-200x and P-300X are equipped with
built-in 12 dB variable electronic crossovers.
Low-pass variable 60 - 150 Hz
High-pass variable 80 - 200 Hz
P-300X: K1-2: HP 80-200 Hz / 2,4 kHz - 6 kHz
K3-4: HP 80 - 200 Hz + LP 3 kHz - 40 kHz
K5: HP 15 - 40 Hz + LP 50 - 125 Hz
The high-pass filters on channel 1-2 and 3-4 can
be switched in-out.
DLS SOUND HANDBOOK - AMPLIFIER DATA