System information
Program 90 : Maintenance Program
90-10 : System Alarm Setup
936 ◆ Programming UX5000 Software Program Manual
Conditions
None
Feature Cross Reference
None
Terminal Programming Instructions
To enter data for Program 90-10 (System Alarm Setup):
1. Enter the programming mode.
2. 90 10
3. Enter the number of the item you want to program.
4. Enter the Alarm number to be defined or press FLASH to use the displayed entry.
5. Enter data for the item you selected + HOLD.
6. Enter data for the next item in the program.
OR
Press MIC once to enter a new item number.
OR
Press MIC until you’ve exited that series’s programming section.
96 1 (MAJ) 0 Database recovery failure.
• File error due to resource
shortage.
Repeat recovery process after
deleting extra files.
97 1 (MIN) 0 Database recovery operation
beginning
98 1 (MIN) 0 Database recovery operation
ending
99 0 0 -- Not Used --
100 0 0 -- Not Used --
90-10-01 Alarm No1
Alarm Type 2:MIN-alrm
back
↑ ↓ select
90-10-nn Alarm Nonn
nnnnn
← − + →
Alarm Type Report Use to Advise Of... Action
Keyset Display Shows . . .
(SID: XX-*** MM/DD HH/MM
XX = CygniLink System ID)