System information

Program 90 : Maintenance Program
90-10 : System Alarm Setup
UX5000 Software Program Manual Programming 935
87 2 (MIN) 0 Daughter Board Synchroni-
zation Fails
Error occurred in commu-
nication between primary
and secondary UX5000s
preventing replication.
LAN link between pri-
mary and secondary
UX5000s disconnected.
Conrm the LAN link
between the primary and sec-
ondary UX5000s.
88 2 (MIN) 0 CygniLink Operation Phase
Shift (Primary)
Operation began as
primary.
89 2 (MIN) 0 CygniLink Operation Phase
shift (Secondary)
Operation began as
secondary.
90 2 (MIN) 0 CygniLink Operation Phase
Shift (Search Mode)
Shifted to node search
mode.
91 2 (MIN) 0 Primary-Automatic Opera-
tion Integration
Primary auto-integration
function performed.
92 2 (MIN) 0 Primary Compulsion
Specication
Primary compulsion
specication function
executed.
93 2 (MIN) 0 CygniLink Node Connection
Detection
Connection of the pri-
mary node for CygniLink
was detected.
94 2 (MIN) 0 CygniLink Node Secession
Detection
Secession of the node was
detected with the Pri-
mary for CygniLink.
95 2 (MIN) 0 Database Replication Fails
(Primary)
Since secondary is in pro-
gram mode, replication of
database cannot be exe-
cuted.
Log out of programming (ter-
minal programming, PCPro,
WebPro) from the secondary
UX5000.
Alarm Type Report Use to Advise Of... Action
Keyset Display Shows . . .
(SID: XX-*** MM/DD HH/MM
XX = CygniLink System ID)