System information

Program 90 : Maintenance Program
90-10 : System Alarm Setup
934 Programming UX5000 Software Program Manual
81 2 (MIN) 0 CygniLink Terminal Call
Trouble Information
DSP resource not
acquired.
Reconrm wiring and
UX5000 data.
82 2 (MIN) 0 CygniLink Virtual Slot
Accommodation Error
Exceeded slot accommo-
dation.
Failure in creating virtual
slot.
Number of slots exceeded.
83 2 (MIN) 0 CygniLink Communication
Error
Checksum error occurred.
Index error occurred.
Router setting incorrect.
LAN connection issue.
Network connection
issue.
Reconrm router settings.
Reconrm LAN connec-
tor and wiring.
Reconrm network settings.
84 2 (MIN) 0 CygniLink License Error
License error occurred
relating to CygniLink.
Expiration date of the
temporary license is
approaching.
Temporary license nulli-
ed.
Conrm license information.
85 2 (MIN) 0 CygniLink Node Connection
Refusal
Connection of secondary
refused in CygniLink.
System ID repeated.
System ID is illegal.
Number of licenses is
insufcient.
Memory shortage.
Conrm the setting and
license information for the
system ID.
86 2 (MIN) 0 Daughter Board Synchroni-
zation Fails
Database versions differ-
ent preventing replica-
tion between UX5000s.
Conrm the versions of data-
bases for the primary and sec-
ondary UX5000s using
PCPro.
Alarm Type Report Use to Advise Of... Action
Keyset Display Shows . . .
(SID: XX-*** MM/DD HH/MM
XX = CygniLink System ID)