System information

Program 90 : Maintenance Program
90-10 : System Alarm Setup
UX5000 Software Program Manual Programming 933
60 2 (MIN) 0 SIP Registration Error Noti-
cation
Registration of SIP trunk
to SIP server failed.
No response from the SIP
server to the SIP registra-
tion request.
Router programming
incorrect.
Problem connecting to
LAN or network.
Reconrm the program-
ming in 10-12, 10-28,
10-29, 10-30, 10-36.
Reconrm router settings.
Reconrm network set-
tings/operation.
Reconrm the authentica-
tion UX5000 data.
Reconrm UX5000 data,
and wiring.
SID:XX-### MM/DD HH:MM
SIP(##) registration request
time-out
SID:XX-### MM/DD HH:MM
SIP(##) registration failure (###)
61 0 0 SIP Extension Error
Notication
Error generated by IP ter-
minal while communicat-
ing with the VOIPDB or
IP terminal.
Reconrm the UX5000
data and wiring.
Conrm equipment opera-
tion (such as access
points).
62 0 0 DtermIP Error Notication
Registration of the SIP
extension failed.
Unable to acquire DSP.
Packet loss occurred on
network.
Reconrm the UX5000
data and wiring.
Conrm HUB operation.
63 0 0 SIP-MLT Trouble
Information
DSP resource not
acquired.
Negotiation with
VOIPDB failed.
Packet loss occurred on
network.
Conrm equipment wir-
ing is correct.
Conrm HUB operation.
64 1 (MAJ) 0 VOIPDB LAN Link Error
LAN cable removed.
HUB defective.
CCPU defective.
Conrm LAN connector
and wiring.
Conrm equipment opera-
tion.
65 0 0 VOIPDB Trouble Informa-
tion
Defective VOIPDB
Replace VOIPDB.
66 2 (MIN) 0 SIP Extension License Error
Number of licenses
exceeded for SIP terminals.
Conrm/increase number of
licenses as needed.
67 0 0 -- Not Used --
:::
80 1 (MAJ) 0 CygniLink Start Error
Defective CCPU possible.
Replace CCPU.
Alarm Type Report Use to Advise Of... Action
Keyset Display Shows . . .
(SID: XX-*** MM/DD HH/MM
XX = CygniLink System ID)