System information

Program 90 : Maintenance Program
90-10 : System Alarm Setup
UX5000 Software Program Manual Programming 931
11 0 0 CTI Link Error
Link to the CTI server
removed.
Connect HUB defective.
CTI server not started
correctly.
Check the CTI server, wiring,
and connection.
12 0 0 ACD MIS Link Error
Link with the ACD MIS
client removed.
Connect HUB defective.
ACD MIS client PC not
started correctly.
Check the ACD MIS client PC
for connection.
13 0 0 Charge Management Link
Error (TMR)
Link with the charge
management device
removed.
Problem with the PC.
Check the wiring, connection,
and PC.
14 0 0 CPU-LAN Link Error
Link between the CPU
and LAN removed.
Connect HUB defective.
CCPU defective.
Reconrm the LAN con-
nector, the LAN wiring,
and HUB.
Replace CCPU is required.
SID:XX-### MM/DD HH:MM
NTCPU battery exchange
15 0 0 CygniLink Keep Alive Error
Link between the CPU
and Network removed
Network side problem.
Packet blocked by re-
wall.
Repetition of IP address.
Reconrm the wiring.
Conrm the network is
functioning properly.
Check the HUB and router
settings and operation.
16 0 0 SMDR LAN Link Error
Link between the CPU
and SMDR removed.
Reconrm the wiring.
17 0 0 -- Not Used --
: : : :
28 0 0 -- Not Used --
Alarm Type Report Use to Advise Of... Action
Keyset Display Shows . . .
(SID: XX-*** MM/DD HH/MM
XX = CygniLink System ID)