System information
Program 90 : Maintenance Program
90-10 : System Alarm Setup
UX5000 Software Program Manual Programming ◆ 931
11 0 0 CTI Link Error
• Link to the CTI server
removed.
• Connect HUB defective.
• CTI server not started
correctly.
Check the CTI server, wiring,
and connection.
12 0 0 ACD MIS Link Error
• Link with the ACD MIS
client removed.
• Connect HUB defective.
• ACD MIS client PC not
started correctly.
Check the ACD MIS client PC
for connection.
13 0 0 Charge Management Link
Error (TMR)
• Link with the charge
management device
removed.
• Problem with the PC.
Check the wiring, connection,
and PC.
14 0 0 CPU-LAN Link Error
• Link between the CPU
and LAN removed.
• Connect HUB defective.
• CCPU defective.
• Reconfirm the LAN con-
nector, the LAN wiring,
and HUB.
• Replace CCPU is required.
SID:XX-### MM/DD HH:MM
NTCPU battery exchange
15 0 0 CygniLink Keep Alive Error
• Link between the CPU
and Network removed
• Network side problem.
• Packet blocked by fire-
wall.
• Repetition of IP address.
• Reconfirm the wiring.
• Confirm the network is
functioning properly.
• Check the HUB and router
settings and operation.
16 0 0 SMDR LAN Link Error
• Link between the CPU
and SMDR removed.
Reconfirm the wiring.
17 0 0 -- Not Used --
: : : :
28 0 0 -- Not Used --
Alarm Type Report Use to Advise Of... Action
Keyset Display Shows . . .
(SID: XX-*** MM/DD HH/MM
XX = CygniLink System ID)