System information

Program 90 : Maintenance Program
90-10 : System Alarm Setup
930 Programming UX5000 Software Program Manual
3 2 (MIN) 0 Communication Error
Between CPU and blade
Blade is not the correct
capacity for the previ-
ously dened slot.
The power supply voltage
is not within the correct
range.
Power supply noise.
Noise from surrounding
equipment.
Improper earth ground.
Remove and reinstall the
blade.
Check the power supply
with a voltmeter for proper
voltage and replace if
needed.
Move external equipment
as far away from the chas-
sis as possible.
Correct the UX5000
grounding.
SID:XX-### MM/DD HH:MM
NTCPU Layer1 link error
4 2 (MIN) 0 Download Error for the blade
Firmware
blade software not stored
in the downloaded USB
memory.
Illegal blade software.
Previously installed blade
software remains.
Use Program 90-05-01 to
delete the blade.
Reload software for blade
from USB memory.
Remove and reinstall the
blade. If not corrected,
replace with a new blade.
5 1 (MAJ) 0 Cooling Fan Error Check the fan operation.
6 0 0 blade Blocking
blade has been blocked in
software.
Terminal wiring not con-
nected or faulty.
External noise.
ESIU blade is defective.
Check the wiring and installa-
tion connections for the blade
and terminal(s).If not cor-
rected, replace with a new
blade.
7 1 (MAJ) 0 Power Failure
UX5000 unplugged.
Power supply may be
defective.
Commercial power is off.
Check the UX5000 AC switch,
fuse and AC outlet. If still
faulty, replace the power supply.
SID:XX-### MM/DD HH:MM
Power failure. Battery operation
8 1 (MAJ) 0 RAM Backup Battery Error
RAM backup battery on
the CPRU blade is
unplugged or defective.
Check the battery connector.
If it is connected correctly,
then replace the battery.
9 0 0 -- Not Used --
10 0 0 ISDN Link Error
Layer link line(s)
removed.
DSU defective.
Program 10-03 not pro-
grammed correctly for
trunk.
Check the wiring and
installation connections
for the DSU and blade.
Check Program 10-03 for
trunk(s).
If not corrected, replace
with a new blade.
Alarm Type Report Use to Advise Of... Action
Keyset Display Shows . . .
(SID: XX-*** MM/DD HH/MM
XX = CygniLink System ID)