System information
Program 90 : Maintenance Program
90-10 : System Alarm Setup
UX5000 Software Program Manual Programming ◆ 929
90-10 : System Alarm Setup
Description
Use Program 90-10 : System Alarm Setup to assign a status to UX5000 alarms. You can desig-
nate an alarm as Major or Minor. This program also assigns whether or not the alarm is displayed to
a key terminal and whether or not the alarm information is reported to the pre-defined destination.
Input Data
Default
Level:
Feature Availability
IN • Available.
Alarm Number 001-100
Item No. Item Input Data
01 Alarm Type 0 = Not set
1 = Major Alarm
2 = Minor Alarm
02 Report 0 = Not reported (No auto-dial)
1 = Report (auto-dial)
Alarm Type Report Use to Advise Of... Action
Keyset Display Shows . . .
(SID: XX-*** MM/DD HH/MM
XX = CygniLink System ID)
1 2 (MIN) 0 Board Initialization Error
• Initialization failure.
• Blade is defective.
• Slot previously defined
for another blade.
• Remove and reinstall the
blade.
• After removing the blade,
delete the slot (Program
90-05) and reinsert the
blade.
• If not corrected, replace
with a new blade.
2 2 (MIN) 0 Board Initial Test Error
• blade is not the correct
capacity for the previ-
ously defined slot.
• blade is out of order.
• Remove and reinstall the
blade.
• If not corrected, replace
with a new blade.