System information
Program 84 : Hardware Setup for VoIP
84-24 : SIP-MLT Codec Information Basic Setup
896 ◆ Programming UX5000 Software Program Manual
84-24 : SIP-MLT Codec Information Basic Setup
Description
Use Program 84-24 : SIP-MLT Codec information Basic Setup to define the codec information
for the SIP multi-line terminals.
Input Data
Level:
Feature Availability
IN • Available.
Type 1 = Type 1
2 = Type 2
3 = Type 3
4 = Type 4
5 = Type 5
Item No. Item Input Data Default
01 Number of G.711 Audio Frame
Maximum number of G711 Audio Frames. When the voice is
encoded using the PCM (Pulse Code Modulation) method, a unit is
a frame of 10ms.
1 = 10 ms
2 = 20 ms
3 = 30 ms
4 = 40 ms
2
02 G.711 Silence Detection (VAD) Mode
Select whether to compress silence with G.711. When there is
silence, the RTP packet is not sent.
0 = Disable
1 = Enable
0
03 G.711 Type
Set the type of G.711.
0 = A-law
1 = µ-law
1
04 G.711 Jitter Buffer - Minimum
Set the minimum value of the G.711 Jitter Buffer.
0~160 ms 20
05 G.711 Jitter Buffer - Standard
Set the average value of the G.711 Jitter Buffer.
0~160 ms 40
06 G.711 Jitter Buffer - Maximum
Set the maximum value of the G.711 Jitter Buffer.
0~160 ms 80
07 G.729 Audio Frame
Maximum number of G729 Audio Frames. G.729 assumes the
audio signal made by a specimen by 8kHz and the frame of 10ms
is assumed to be a unit to 8kbps by the encoding compressed
method.
1-4
(1 = 10ms,
2 = 20ms, etc.)
2
08 G.729 Silence Compression (VAD) Mode
Select whether to compress silence with G.729. When there is
silence, the RTP packet is not sent.
0 = Disable
1 = Enable