System information

Program 10 : System Conguration Setup
10-28 : SIP Trunk Basic Setup
UX5000 Software Program Manual Programming 75
10-28 : SIP Trunk Basic Setup
Description
Use Program 10-28 : SIP Trunk Basic Setup to set the basic options used for SIP trunks.
Input Data
Conditions
None
Level:
Feature Availability
SA Available.
Item
No.
Item Input Data Default
Related
Program
01 Domain Name
Dene the Domain name. This information is
generally provided by the SIP carrier.
64 characters maximum None
02 Host Name
Dene the Host name. This information is gener-
ally provided by the SIP carrier.
48 characters maximum None
03 Transport Protocol
Dene the Transport type. This option will
always be set to UDP.
0 = UDP
1 = TCP
0
04 User ID
Dene the User ID. Note: If Program 10-23-04
for UX5000 interconnection, this entry must be
numeric as 10-23-04 does not allow text entry -
only numeric. This information is generally pro-
vided by the SIP carrier.
32 characters maximum No Entry 21-17
21-19
05 Domain Assignment
Dene the Domain Assignment. This entry is
determined by what information the SIP carrier
provides. If the SIP carrier provides a server
name: SIPconnect-sca.atL0.cbeyond.net, then
the domain would be: atL0.cbeyond.net and the
host name would be SIPconnect-sca.
0 = IP Address
1 = Domain name
0
06 IP Trunk Port Binding
If this entry is set to 0 (Disable), an incoming
call uses the lowest port. If the entry is set to 1
(Enable), the incoming call uses the port
assigned in 10-36. This could be required if a
carrier provides more than one registration (one
for each telephone number provided).
0 = Disable
1 = Enable
0 10-36-01