System information
Program 82 : Basic Hardware Setup for Extension
82-05 : ISDN BRI & PRI Layer 2 (S-Point) Initial Data Setup
828 ◆ Programming UX5000 Software Program Manual
82-05 : ISDN BRI & PRI Layer 2 (S-Point) Initial Data Setup
Description
Use Program 82-05 : ISDN BRI & PRI Layer 2 (S-Point) Initial Data Setup to define the vari-
ous basic options for the layer 2 of ISDN BRI/PRI S-Point.
Input Data
Conditions
● This program will not be displayed in PCPro/WebPro until signing in with the MF level
password.
Feature Cross Reference
● ISDN Compatibility
Level:
Feature Availability
IN • Available.
Item No. Item Input Data Default
01 Timer T200 1-255 (100-25500ms) 10 (1 sec.)
02 Timer T201 1-255 (100-25500ms) 10 (1 sec.)
03 Timer T202 1-255 (100-25500ms) 20 (2 sec.)
04 Timer T203 1-255 (100-25500ms) 30 (3 sec.)
05 N200 1-255 3
06 N201 1-65535 (Byte) 260
07 N202 1-255 3