System information

Program 82 : Basic Hardware Setup for Extension
82-04 : SLIU Initial Data Setup
826 Programming UX5000 Software Program Manual
82-04 : SLIU Initial Data Setup
Description
Use Program 82-04 : SLIU Initial Data Setup to dene the various basic timers for the ASTU
blade.
Input Data
Conditions
This program will not be displayed in PCPro/WebPro until signing in with the MF level
password.
Feature Cross Reference
None
Level:
Feature Availability
IN Available.
Item No. Item Input Data Default
01 Companding Method type 0 = u-law
1 = A-law
0 (u-law)
02 Ringing frequency 0 = 25Hz
1 = 20Hz
2 = 16Hz
1 (20Hz)
03 Minimum break time 1-255 (5ms-1275ms) 2 (10ms)
04 Maximum break time 1-255 (5ms-1275ms) 20 (100ms)
05 Minimum make time 1-255 (5ms-1275ms) 2 (10ms)
06 Maximum make time 1-255 (5ms-1275ms) 20 (100ms)
07 Minimum hook ash time 1-255 (5ms-1275ms) 21 (105ms)
08 Maximum hook ash time 1-255 (5ms-1275ms) 200 (1000ms)
09 Minimum ground ash time 1-255 (5ms-1275ms) 21 (105ms)
10 Minimum off-hook time 1-255 (5ms-1275ms) 21 (105ms)
11 No detection time after off-hook 1-255 (5ms-1275ms) 60 (300ms)
12 No detection time after pulse dial detection 1-255 (5ms-1275ms) 70 (350ms)
13 Loop disconnect time, Reversal time 1-255 (10ms-2550ms) 60 (600ms)
14 Ring, Message wait period time 1-255 (5ms-1275ms) 150 (750ms)