System information

Program 81 : Basic Hardware Setup for Trunk
81-03 : 4TLIU Initial Data Setup
806 Programming UX5000 Software Program Manual
81-03 : 4TLIU Initial Data Setup
Description
Use Program 81-03 : 4TLIU Initial Data Setup to dene the various basic timers for the E&M tie
line blade.
Input Data
Level:
Feature Availability
IN Available.
Item No. Item Input Data Default
01 Companding method type 0 = u-law
1 = A-law
0 (u-law)
02 Answer Signal Time 1-255 (10-2550mS) 6 (60mS)
03 Clear Signal (Open Loop) Detection Time 1-255 (100-25500mS) 7 (700mS)
04 Ringing Signal Detection Min. Time 1-255 (10-2550mS) 10 (100mS)
05 Ringing Signal Stop Detection Time 1-255 (100-25500mS) 7 (700mS)
06 Hook Flash Time 1-255 (10-2550mS) 20 (200mS)
07 Pause Time 1-255 (60-15300mS) 50 (3000mS)
08 WINK/DELAY Duration Time 1-255 (10-2550mS) 20 (200mS)
09 Incoming-WINK/DELAY Send Time 1-255 (100-25500mS) 3 (300mS)
10 Seizure-WINK/DELAY Receive Max. Time 1-255 (100-25500mS) 48 (4800mS)
11 Receive WINK/DELAY Duration Min. Time 1-255 (10-2550mS) 13 (130mS)
12 Receive WINK/DELAY Duration Max. Time 1-255 (10-2550mS) 31 (310mS)
13 Receive DP Make Min. Time 1-255 (2-510mS) 5 (10mS)
14 Receive DP Make Max. Time 1-255 (2-510mS) 50 (100mS)
15 Receive DP Break Min. Time 1-255 (2-510mS) 5 (10mS)
16 Receive DP Break Max. Time 1-255 (2-510mS) 50 (100mS)
17 Pause Time After WINK/DELAY Receive 1-255 (8-2040mS) 13 (104mS)
18 Loop Off Guard Time 0-255 (0,100-25500mS) 20 (2000mS)
19 DP Break Time (10pps) 1-255 (2-510mS) 32 (64mS)
20 DP Make Time (10pps) 1-255 (2-510mS) 16 (32mS)
21 DP Inter-Digit Time (10pps) 1-255 (32-8160mS) 19 (608mS)
22 DP Break Time (0pps) 1-255 (2-510mS) 16 (32mS)
23 DP Make Time (20pps) 1-255 (2-510mS) 8 (16mS)
24 DP Inter-Digit Time (20pps) 1-255 (32-8160mS) 16 (512mS)