System information

Program 81 : Basic Hardware Setup for Trunk
81-02 : DIOPU Initial Data Setup
804 Programming UX5000 Software Program Manual
81-02 : DIOPU Initial Data Setup
Description
Use Program 81-02 : DIOPU Initial Data Setup to dene the various basic timers for the DIOPU
cards.
Input Data
Level:
Feature Availability
IN Available.
Item
No.
Item Input Data Default
01 Companding method type 0 = u-law
1 = A-law
0 (u-law)
02 Answer Signal Time 1-255 (10-2550mS) 6 (60mS)
03 Clear Signal (Open Loop) Detection Time 1-255 (100-25500mS) 7 (700mS)
04 Ringing Signal Detection Min. Time 1-255 (10-2550mS) 10 (100mS)
05 Hook Flash Time 1-255 (8-20240mS) 25 (200mS)
06 Pause Time 1-255 (32-8160mS) 94
(3008mS)
07 WINK/DELAY Duration Time 1-255 (10-2550mS) 20 (200ms)
08 Incoming-WINK/DELAY Send Time 1-255 (100-25500mS) 3 (300mS)
09 Seizure-WINK/DELAY Receive Max. Time 1-255 (100-25500mS) 48
(4800mS)
10 Receive WINK/DELAY Duration Min. Time 1-255 (10-2550mS) 13 (130mS)
11 Receive WINK/DELAY Duration Max. Time 1-255 (10-2550mS)
1-255 (8-20240mS)
31 (310mS)
12 Receive DP Make Min. Time 1-255 (2-510mS) 5 (10mS)
13 Receive DP Make Max. Time 1-255 (2-510mS) 50 (100mS)
14 Receive DP Break Min. Time 1-255 (2-510mS) 5 (10mS)
15 Receive DP Break Max. Time 1-255 (2-510mS) 50 (100mS)
16 Receive DP Inter-Digit Time 1-255 (32-8160mS) 6 (192mS)
17 Loop Off Guard Time 0-255 (0,100-25500mS) 20
(2000mS)
18 DP Break Time (10pps) 1-255 (4-1020mS) 16 (64mS)
19 DP Make Time (10pps) 1-255 (4-1020mS) 8 (32mS)
20 DP Inter-Digit Time (10pps) 1-255 (16-4080mS) 38 (608mS)
21 DP Break Time (0pps) 1-255 (4-1020mS) 8 (32mS)
22 DP Make Time (20pps) 1-255 (4-1020mS) 4 (16mS)