System information

Program 81 : Basic Hardware Setup for Trunk
81-01 : COIU Initial Data Setup
802 Programming UX5000 Software Program Manual
Conditions
This program will not be displayed in PCPro/WebPro until signing in with the MF level
password.
Feature Cross Reference
Central Ofce Calls, Placing
15 Flash (Hooking 2)
This sets the ash (Hooking 2) duration for analog trunk calls. See Pro-
gram 14-02-04.
1-255 (16-4080mS) 156 (2496ms)
16 Pause Time 1-255 (64-16320mS) 16 (1024ms)
17 PFT Idle Detection Time 1-255 (64-16320mS) 47 (3008ms)
18 Grounding Start Time 1-255 (8-2040mS) 6 (48ms)
19 Grounding Start Give-Up Time 1-255 (64-16320mS) 47 (3008ms)
20 Loop Reverse Detect Minimum Time 1-255 (8-2040mS) 13 (104ms)
21 Loop Reverse Detect Maximum Time 1-255 (8-2040mS) 107 (856ms)
22 Loop Disconnect Detect Minimum Time 1-255 (8-2040mS) 50 (400ms)
23 Loop Disconnect Detect Maximum Time 1-255 (8-2040mS) 80 (640ms)
24 On Hook Normal Detect Time 1-255 (8-2040mS) 2 (24ms)
25 On Hook Reverse Detect Time 1-255 (8-2040mS) 2 (16ms)
26 On Hook Disconnect Detect Time 1-255 (16-4080mS) 188 (3008ms)
27 Pulse Dial Break Time (10pps) 1-255 (8-2040mS) 8 (32ms)
28 Pulse Dial Make Time (10pps) 1-255 (8-2040mS) 5 (40ms)
29 Inter-Digit Time (10pps) 1-255 (32-8160mS) 25 (800ms)
30 Pulse Dial Break Time (20pps) 1-255 (8-2040mS) 4 (32ms)
31 Pulse Dial Make Time (20pps) 1-255 (8-2040mS) 2 (16ms)
32 Inter-Digit Time (20pps) 1-255 (32-8160mS) 16 (512ms)
33 Charging Pulse Minimum Duration Time 1-255 (8-2040mS) 9 (72ms)
34 Charging Pulse Minimum Period Time 1-255 (8-2040mS) 29 (232ms)
35 Charging Pulse Minimum Interval Time 1-255 (8-2040mS) 6 (48ms)
36 Long Ringing Minimum Detection Time 1-255 (16-4080mS) 50 (2400ms)
Item
No.
Item Input Data Default