System information
Program 80 : Basic Hardware Setup for System
80-10 : MF Tone Receiver Setup
798 ◆ Programming UX5000 Software Program Manual
80-10 : MF Tone Receiver Setup
Description
Use Program 80-10 : MF Tone Receiver Setup to define the various levels and timers for the MF
Tone Receiver
Input Data
Input Data
Level:
Feature Availability
MF • Not Available.
MF Tone Receiver Type Number 1 = MF Receiver for Extension
2 = MF Receiver for Trunk
3 = -- Reserve --
4 = -- Reserve --
5 = -- Reserve --
Item No. Item Input Data
01 Detect Level 0 : 0dBm to -25dBm
1 : -5dBm to -30dBm
2 : -10dBm to -35dBm
3 : -15dBm to -40dBm
4 : -20dBm to -45dBm
5 : -25dBm to -50dBm
6 : -30dBm to -55dBm
02 Start Delay Time 0-255 (0.25step, 0ms-64ms)
03 Minimum Detect Level 0-15
detect level 0 : -10dBm(0) to -25dBm(15)
detect level 1 : -15dBm(0) to -30dBm(15)
detect level 2 : -20dBm(0) to -35dBm(15)
detect level 3 : -25dBm(0) to -40dBm(15)
detect level 4 : -30dBm(0) to -45dBm(15)
detect level 5 : -35dBm(0) to -50dBm(15)
detect level 6 : -40dBm(0) to -55dBm(15)
04 Maximum Detect Level 0-15
detect level 0 : 0dBm(0) to -15dBm(15)
detect level 1 : -5dBm(0) to -20dBm(15)
detect level 2 : -10dBm(0) to -25dBm(15)
detect level 3 : -15dBm(0) to -30dBm(15)
detect level 4 : -20dBm(0) to -35dBm(15)
detect level 5 : -25dBm(0) to -40dBm(15)
detect level 6 : -30dBm(0) to -45dBm(15)
05 Twist Level 0-9 (1dB…10dB)
06 S/N Ratio 0-4 (-5 step, 0dB to -20dB)
07 ON Detect Tme 1-255 (15 step, 30ms to 3840ms)
08 OFF Detect Tme 1-255 (15step, 30ms to 3840ms)