System information
Program 80 : Basic Hardware Setup for System
80-04 : Call Progress Tone Detector Setup
792 ◆ Programming UX5000 Software Program Manual
Default
Conditions
● This program will not be displayed in PCPro/WebPro until signing in with the MF level
password.
● The UX5000 must be reset in order for any changes to these items take affect.
11 -- Reserve -- 0-8
12 -- Not Used in U.S. -- -
13 -- Not Used in U.S. -- -
14 -- Not Used in U.S. -- -
Item
No.
Item
Type1
(DT)
Type2
(BT)
Type3
(RBT)
Type4 Type5
01 Detect Level 0
(0..-25dBm)
0
(0..-25dBm)
0
(0..-25dBm)
00
02 Min. detect
level
15
(-25dBm)
15
(-25dBm)
15
(-25dBm)
00
03 S/N ratio 4
(-20dB)
4
(-20dB)
4
(-20dB)
00
04 No tone time 132
(3990ms)
132
(3990ms)
132
(3990ms)
00
05 Pulse Count 11100
06 ON min. time 9 (300ms) 12
(390ms)
25
(780ms)
00
07 ON max. time 0
(Not detect)
20
(630ms)
40
(1230ms)
00
08 OFF min. time 1
(60ms)
12
(390ms)
83
(2520ms)
00
09 OFF max. time 1
(60ms)
20
(630ms)
115
(3480ms)
00
10 -- Reserve -- 11100
11 -- Reserve -- 00000
12 Frequency 1 1 3 2 1 1
13 Frequency 2 2 4 3 0 0
14 Twist Level 00000