System information

Program 80 : Basic Hardware Setup for System
80-01 : Service Tone Setup
UX5000 Software Program Manual Programming 779
Program 80 : Basic Hardware Setup for System
80-01 : Service Tone Setup
Description
Use Program 80-01 : Service Tone Setup to dene up to 64 Service Tones. Each service tone is
dened by the combination of 32 Basic Tones.
Input Data
Table-1A : Basic Tone
Level:
Feature Availability
IN Available.
Service Tone Number 01-64
Item No. Item Input Data
01 Repeat Count 0-255 (0 is endless)
Unit Number 1-8
Item No. Item Input Data
02 Basic Tone Number 1-33 (0=No Tone, 33=Default Time Slot)
03 Duration Count 0, 1-255 (0, 100-25500ms)
04 Gain Level (dB) 0, 1-63 (0, -15.5 ~ +15.5)
Basic
Tone No.
Frequency (Hz) Level (dB)
Basic
Tone No.
Frequency (Hz) Level (dB)
01 400 - 13 17 520 / 650 -13 / -19
02 520 -13 18 650 / 780 -13 / -19
03 580 -13 19 780 / 1040 -13 / -19
04 660 -13 20 1040 -13
05 700 -13 21 450 -13
06 800 -13 22 950 -13
07 880 -13 23 1800 -13
08 1050 -13 24 400 / 450 -13 / -13
09 350 / 440 -16 / -16 25 - reserve - -
10 440 / 480 -16 / -16 26 - reserve - -