System information
Program 51 : CygniLink Service
51-16 : CygniLink System Data Replication Mode Setting
776 ◆ Programming UX5000 Software Program Manual
51-16 : CygniLink System Data Replication Mode Setting
Description
Use Program 51-16 : CygniLink System Data Replication Mode Setting to define the replica-
tion mode to be used for data between the Primary and Secondary UX5000s.
Input Data
Conditions
None
Feature Cross Reference
● Networking - CygniLink
Level:
Feature Availability
IN • Available.
Item Name Input Data Default
01 System Data Replication Mode
Use this option to set the replication mode. An entry of
‘1’ will replicate the data at the time set in 51-16-02. If
this option is set to ‘2’, replication will occur at the
interval set in 51-16-03.
0=Disabled
1=Setting Time Mode
2=Interval Mode
0
02 System Data Replication Time Setting
If Program 51-16-01 is set to ‘1’, set the time to repli-
cate the UX5000 data.
0000-2359 0200
03 System Data Replication Interval Setting
If Program 51-16-01 is set to ‘2’, set the interval time
between replicating the UX5000 data.
15-1440 (Min) 30 (min)
04 Replication Time Stamp
This program displays the last time the UX5000 data
was replicated. This is automatically updated when-
ever the replication occurs.
This option is view-only.
Month: 0~12
Day: 00~31
Hour: 00~23
Minute: 00~59
-
05 System Data Replication Wait Time
When a CygniLink network is created, this option deter-
mines how long the UX5000 waits until replication is
started.
1-86400 (seconds)
(86400 seconds = 1 day)
180 sec (3 min)
06 System Data Replication Interval
This option sets the interval time to start replication to
the next node after replication has completed to one
node.
0-86400 (seconds)
(86400 seconds = 1 day)
1 (sec)