System information

Program 51 : CygniLink Service
51-13 : CygniLink Option Settings
770 Programming UX5000 Software Program Manual
51-13 : CygniLink Option Settings
Description
Use Program 51-13 : CygniLink Option Settings to set various options for the CygniLink
feature.
Input Data
Conditions
None
Feature Cross Reference
Networking - CygniLink
Level:
Feature Availability
IN Available.
Item No. Item Input Data Default
01 Automatic IP Address List Update
If this option is enabled, the Internet Protocol
address list is updated to include the IP address
of a Secondary UX5000 upon connection.
0=Disabled
1=Enabled
1
02 Time Zone Enhancing
When enabled, the time zone is applied to the
following items:
Clock Display
Caller ID History
VRS Time Announce
Time and Date Set by Service Code
Alarm Clock
Hotel Mode Wake-Up Call (time announce
included)
0=Disabled
1=Enabled
0
03 MAC Address Authentication
When enabled, connection authentication of the
UX5000 is done with the MAC address set in
Program 51-02-04.
0=Disabled
1=Enabled
0