System information
Program 51 : CygniLink Service
51-09 : CygniLink TCP Port Settings
764 ◆ Programming UX5000 Software Program Manual
Conditions
● The port numbers should not be changed while CygniLink is running. Once changed, the
UX5000 must be reset.
Feature Cross Reference
● Networking - CygniLink
Terminal Programming Instructions
To enter data for Program 51-09 (CygniLink TCP Port Settings):
1. Enter the programming mode.
2. 51 09
3. Enter the number of the item you want to program.
4. Enter data for the item you selected + HOLD.
5. Enter data for the next item in the program.
OR
Press MIC once to enter a new item number.
OR
Press MIC until you’ve exited that series’s programming section.
07 Database Replication Primary System
Detection Port
Define the port used for communication so
that the Primary UX5000 may synchronize the
Secondary UX5000 with the UX5000 data. If
‘0’ is entered, the port is selected dynamically.
0-65535 0
51-09-01
Listening Port 58000
back
↑ ↓ select
51-09-nn
nnnnn
← →
Item No. Item Input Data Default